TBL501000-1 50uH Line Impedance Stabilization Network LISN – CISPR 16

50uH Line Impedance Stabilisation Network LISN – CISPR 16

High-current, single-path 50 µH LISN for conducted-emissions measurements on AC- or DC-powered equipment.

  • LISN type: single path V-AMN, 50OHM // 50µH; no 250µH pre-filter
  • Characterized Frequency range: 100 kHz – 30 MHz
  • DC Resistance: < 3 mOHM Maximum current: 1000 A continuous with fan ON; 500 A continuous without fan Operating voltage range: 0 – 1000V DC; 0 – 500V AC (50/60 Hz) High pass to suppress residual AC: default jumpered ON; residual AC suppression > 66dB; RF out not terminated
  • EUT connector: High current wing terminal, M16 x 1.5
  • Source connector: High current wing terminal, M16 x 1.5

TBL501000-1 Technical Document

SPECIFICATIONS

TBL501000-1 50uH Line Impedance Stabilization Network LISN – CISPR 16

High-current, single-path 50 µH LISN for conducted-emissions measurements on AC- or DC-powered equipment.

Technical specifications

LISN type single path V-AMN, 50OHM // 50µH; no 250µH pre-filter
Characterized Frequency range 100 kHz – 30 MHz
DC Resistance < 3 m? Maximum current: 1000 A continuous with fan ON; 500 A continuous without fan Operating voltage range: 0 – 1000V DC; 0 – 500V AC (50/60 Hz) High pass to suppress residual AC: default jumpered ON; residual AC suppression > 66dB; RF out not terminated
EUT connector High current wing terminal, M16 x 1.5
Source connector High current wing terminal, M16 x 1.5
Earth Exposed stainless steel profile with mounting slots
RF connector N-Female
Fan Available with 100V-120V or 220V-240V supply voltage; C14 connector with integrated switch on rear panel
Dimensions W x H x L; 480 mm x 600 mm x 660 mm;
Weight 70 kg
  EMC conducted noise measurements