TBL5008-2C 50µH Line Impedance Stabilization Network

50µH Line Impedance Stabilisation Network

C-version two-line 50 µH mains LISN for conducted-emissions testing from 9 kHz to 30 MHz.

  • Frequency range: 9 kHz to 30 MHz
  • Impedance: 50 OHM || (50 µH + 5 OHM)
  • Artificial hand: 220 pF + 511 OHM
  • Switchable PE: 50 OHM || 50 µH
  • Limiter / attenuator / highpass filter: +6dBm / 10 dB /150 kHz to 30 MHz

TBL5008-2C Technical Document

SPECIFICATIONS

TBL5008-2C 50µH Line Impedance Stabilisation Network

C-version two-line 50 µH mains LISN for conducted-emissions testing from 9 kHz to 30 MHz.

Technical specifications

Frequency range 9 kHz to 30 MHz
Impedance 50 OHM || (50 µH + 5 OHM)
Artificial hand 220 pF + 511 OHM
Switchable PE 50 OHM ? 50 µH
Limiter / attenuator / highpass filter +6dBm / 10 dB /150 kHz to 30 MHz
  Air core inductors
Line voltage max. 250V / 50/ 60 Hz or DC
Max. current 8 A @ 23°C
EUT socket country specific
Measurement connector 50 OHM BNC
Power connector IEC 60320 C13
Operating Temperature Range +5°C … + 40°C; 5% to 80% RH