The Combination Wave Generator CWG-CE7 is a combined impulse-current-/impulse-voltage generator which, for high-impedance loads, RL > 100?, delivers a standard impulse voltage with waveform 1.2/50?s and, for short-circuited output, a standard impulse current with waveform 8/20?s.
PARTNER:
MARKETS:
TEST STANDARDS:
Multi CE7
IEC 61000-4-05, IEC 61000-4-09
According to |
|
IEC 61000-4-5 : 2014 |
SURGE 7kV, 3.5kA |
IEC 61000-4-9 : 2001 |
Magnetic field 8/20 µs |
ITU, FCC part 68 and IEC 61000-4-5 |
Telecom Surge 7kV |
The CWG-CE7 is a compact EMC test unit designed for testing electromagnetic immunity against pulsed and conducted interference. Demonstrating such immunity is generally a requirement for compliance with the European EMC directive, a necessary step leading to the CE mark.
The Combination Wave Generator fully compliant to IEC 61000-4-5 and IEEE 587 delivers a standard impulse voltage with waveform 1.2/50 µs and a standard impulse current with waveform 8/20 µs. It is a combined impulse-current-/impulse-voltage generator for high- impedance loads RL > 100W and may be used for surge testing of components and devices, as well as for galvanic coupling of surges to cable shields, shielded enclosures, and cabinets.
The built-in capacitive Coupling-/Decoupling Network allows the superimposition of the combination wave generator output to the mains voltage of the device under test.
An Induction Coil in conjunction with the Combination Wave Generator output is used to simulate pulsed magnetic fields according to IEC 61000-4-9.
The CWG-CE7 excels by its compact design, simple handling and precise reproducibility of test impulses. It features a microprocessor-controlled user interface and a 7” touch screen unit for ease of use. The microprocessor allows the user to execute either standard test routines or a “user-defined” test sequence. A standard USB port provides the ability to print a summary of the test parameters as well as the results to a USB stick.
The software program CE-REMOTE allows full remote control of the test generator via Ethernet light guide as well as documentation and evaluation of test results, accordingly to the IEC 17025. To record definite impulses, it is equipped with an Impulse Recording Function (IRF).
Moreover all generator functions including the built-in Coupling-/Decoupling Network, maybe computer-controlled via the isolated optical interface.
System configuration
Variations |
Description |
Multi-CE7 1 |
including SURGE and BURST |
Multi-CE7 2 |
including SURGE, BURST, and POWER FAIL SWITCH |
EFTG-CE5 |
Stand-alone BURST generator |
CWG-CE7 |
Stand-alone SURGE generator |
PFS-CE-16 |
Stand-alone POWER FAIL SIMULATOR Including a power fail switch and a variable power source |
It is possible to build all devices in a 19” rack cabinet.
Options |
CWG CE7 |
|
|
Software CE-REMOTE Test, for remote control |
|
With Impulse Recording Function (IRF) |
|
( XP, WIN7, WIN10 ) incl. 5 m fiber optic cable and PC Ethernet interface |
|
|
|
External power source VPS 250-16 |
|
Output voltage, adjustable |
0 - 250 V |
Rated current |
16 A |
Control via interface of Multi CE7 |
|
|
|
Induction Coil HI 200 acc. to IEC 61000-4-8/9: 2010/2001 |
|
Dimensions: W * H * D |
1000*1000*600 mm3 |
Coil factor |
1.5 / m |
|
|
EFTC2012 Coupling Clamp acc. to IEC 61000-4-4:2012 Ed 3.0 |
|
Dimensions: W * H * D |
140 * 180 *1100 mm³ |
Incl. Connection cable, Fischer Koax Connector |
1 m long |
Maximum cable diameter: |
ca. 42mm |
TECHNICAL SPECIFICATIONS |
Multi CE7 |
|
|
Mainframe |
|
Microprocessor controlled touch panel |
7”, capacitive |
Optical Ethernet Interface for remote control of the generator |
optional |
Interface for saving reports |
USB |
External trigger input/ output |
Switch/ 10 V |
Coupling-/decoupling network for power supply lines |
L1, N, PE (ISO, optional ANSI) |
Nominal voltage, nominal current |
250 V, 16 A » / 16 A = |
Coupling impedance (depending on the generator) |
33 nF / 18 µF / 9µF+10W |
Connector for external safety interlock loop |
24 V = |
External red and green warning lamps |
230 V, 60W |
Mains power |
90V - 264V, 50/60 Hz |
Dimensions of desktop case W * H * D |
450*330*500 mm3 |
Weight |
25 kg |
|
|
SURGE acc. to IEC 61000-4-5: 2014 |
|
Test voltage (open circuit condition) |
0.25 - 7.0 kV ± 10 % |
Waveform acc. to IEC 60060 |
1.2 / 50 µs ± 20 % |
Test current (short circuit condition) |
0.25 - 3.5 kA ± 10 % |
Waveform acc. to IEC 60060 |
8 / 20 µs ± 20% |
Polarity of output voltage/current, selectable |
pos/neg/alt |
Maximum stored energy |
250 Joule |
Charging time for max. charging voltage |
< 20 s |
HV output isolated from ground |
HV-OUT, 4mm |
Mains synchronous triggering, phase shifting, digitally selectable |
0 - 359°, step 1° |
Monitor output for pulse output voltage |
ratio = 1000 : 1 ± 5% |
Monitor output for pulse output current |
10 V º 5 kA ± 5% |