The measurement mode switch CMDM 8700 B expands the measurement possibilities of two V-LISN to T- and Delta-LISNs for the profound analysis of interference emissions.
CMDM 8700 B Common mode / Differential mode switchThe measurement mode switch CMDM 8700 B expands the measurement possibilities of two V-LISN to T- and Delta-LISNs for the profound analysis of interference emissions. You can measure the signals in four different ways:
If the mode switch is set to “Line A” or “Line B” the unsymmetrical signals of the inputs A or B will be measured directly. The line which is not used at the moment will be terminated with 50 Ω internally. (V-LISN) If the switch is set to the position “Common Mode” the common asymmetrical components of both inputs will be measured. (T-, Delta-LISN) If the switch is set to „Differential Mode“ the CDMD 8700 B extracts the symmetrical components (common-mode voltage) and routes them to the measurement output. (Delta-LISN)
To protect the measurement receiver from low-frequency interferences (below 7 kHz) there is a built-in high pass filter at the output. Measurements using the different operation modes allow to find the source of interference easier and to take steps to eliminate them. As for instance to suppress conducted common-mode interferences common-mode chokes are used and bypass capacitors are connected to ground. When differential mode interferences occur you need to connect capacitors between the lines.
|