Coil Set 14708-7, Test set for testing to ISO 14708-7 A/B levels

LF Transmit Coil (CABTL16 & CABTL11)

  • Frequency: 16.6 Hz - 27MHz
  • 2 loop sets
  • Meets ISO 14708-7 Criteria A and High B levels
  • Use 100 Watt Audio amplifier up to 35kHz
  • Use 150 Watt 50Ohm amplifier 25 kHz - 27 MHz 

 

SPECIFICATIONS

Coil Set 14708-7 For testing ISO 14708-7 Critiea B 

Overview

The CABTL Series Transmit Loops are designed for precise EMC testing applications, specifically to meet ISO 14708-7 Criterion B requirements as outlined in Table 2. These loops are constructed on a Delrin former with an adjustable EUT stand, making them versatile for field measurement tasks. The loops ensure accurate positioning of the Equipment Under Test (EUT), with the field measurement taken at the center of the coil. The EUT must be centrally positioned within the loop for optimal results.

ISO 14708-7 Loops:

CABTL16 - Custom Transmit Loop

  • Frequency Range: 16 Hz – 700 kHz

  • Coil Diameter: 16 cm

  • Design: Constructed on a Delrin former with a central, adjustable EUT stand.

  • Application: Designed for ISO 14708-7 Criterion B in Table 2.

  • Field Measurement: Performed at the center of the coil. The EUT must be placed in the center of the coil for accurate results.

  • Included: EUT spacer, Loop Holder Spacer

CABTL11 - Transmit Loop

  • Frequency Range: 700 kHz – 27 MHz

  • Coil Diameter: 11 cm

  • Connectors: Equipped with 4x Type N connectors for each band, enabling different configuration options:

    • 700 kHz - 5 MHz: Direct connection

    • 5 MHz – 6.8 MHz: Matching Network to 50 Ohms

    • 6.8 MHz – 10 MHz: Matching Network to 50 Ohms

    • 10 MHz – 27 MHz: Matching Network to 50 Ohms

  • Design: Mounted on a Delrin form with a central, adjustable EUT stand.

  • Application: Designed for ISO 14708-7 Criterion B in Table 2.

  • Field Measurement: Performed at the center of the coil. The EUT must be placed in the center of the coil for accurate measurement.

  • Included: EUT spacer, Loop Holder Spacer

Includes measurement accessories. High-Frequency Sense Coil (CABLSHF) 150 kHz - 26 MHz, 0.5Ohm Shunt resistor CABCI250RHelmholtz sensor HS-5136

 

Key Features:

  • Precise Field Measurement: The loops are engineered to ensure the EUT is positioned accurately for consistent and reliable field measurement.

  • Adjustable EUT Stand: The central EUT stand is adjustable, allowing flexibility to accommodate different EUT sizes and ensuring optimal positioning.

  • Delrin Construction: The Delrin former construction provides a non-conductive and robust frame that minimizes electromagnetic interference during testing.

  • Multiple Connector Options (CABTL11): The CABTL11 model is fitted with 4 Type N connectors to facilitate different frequency bands with matching networks, ensuring precise impedance matching and enhanced performance.


Applications:

  • Designed primarily for ISO 14708-7 Criterion B testing requirements, which involve EMC testing for medical devices and implants.

  • Suitable for testing scenarios that require low-frequency and high-frequency electromagnetic exposure in a controlled environment.

 

Specifications:

ModelFrequency RangeCoil DiameterConnectorsMatching Network
CABTL16 16 Hz – 700 kHz 16 cm 1x Type N N/A
CABTL11 700 kHz – 27 MHz 11 cm 4x Type N (per band) Yes (50 Ohms)

 

OTHER PRODUCTS IN THE SAME CATEGORY:
Loading...