100 kHz to 6 GHz | 30 dB gain | SMA | 50 ohm
The Langer PA 306 SMA Set amplifies weak near-field probe signals for EMC troubleshooting. Noise figure 3 dB. Supply 12 V DC at 100 mA. Includes the amplifier, plug-in power supply and system case.
MARKETS:
CATEGORIES:
TEST STANDARDS:
Covers signals below 10 MHz and extends to 6 GHz. Use it to raise low-level RF signals before a spectrum analyzer or a 50 ohm oscilloscope input when tracing emissions from PCBs and ICs.
| Parameter | Specification |
|---|---|
| Frequency range | 100 kHz to 6 GHz |
| Gain | 30 dB |
| RF connectors | SMA input and output |
| RF impedance | 50 ohm |
| Noise figure | 3 dB |
| Output 1 dB compression point | +10 dBm |
| Maximum RF input power | +13 dBm |
| DC supply voltage | 12 V DC |
| Current consumption | 100 mA |
| Amplifier weight | 50 g |
| Amplifier dimensions | 50 x 38 x 13 mm |
| Set weight | 400 g |
| Item | Qty. | Description |
|---|---|---|
| PA 306 SMA | 1 | SMA RF preamplifier |
| NT FRI EU | 1 | Plug-in power supply listed on the set sheet. Confirm the regional plug when ordering. |
| Case 5 | 1 | System case |


Connect the near-field probe to the amplifier input with a 50 ohm coaxial cable rated for the band of interest. Connect the output to the instrument and power the amplifier with the supplied adapter. Account for amplifier gain and cable loss when interpreting absolute signal levels. Check both amplifier compression and the instrument input limit when strong signals are present.
| Photo | Model | Frequency range | RF ports | Gain | Noise figure | Output P1dB |
|---|---|---|---|---|---|---|
![]() |
PA 203 BNC Set | 100 kHz to 3 GHz | BNC | 20 dB | 4.5 dB | 0 dBm |
![]() |
PA 203 SMA Set | 100 kHz to 3 GHz | SMA | 20 dB | 4.5 dB | 0 dBm |
![]() |
PA 303 BNC Set | 100 kHz to 3 GHz | BNC | 30 dB | 4.5 dB | +10 dBm |
![]() |
PA 303 SMA Set | 100 kHz to 3 GHz | SMA | 30 dB | 4.5 dB | +10 dBm |
![]() |
PA 303 N Set | 100 kHz to 3 GHz | N-type | 30 dB | 4.5 dB | +10 dBm |
![]() |
PA 306 SMA Set | 100 kHz to 6 GHz | SMA | 30 dB | 3 dB | +10 dBm |
![]() |
PA 3010 Set | 10 MHz to 10 GHz | SMA | 30 dB typ. | 2.5 dB typ. at 5 GHz | +18 dBm typ. at 5 GHz |
![]() |
PA 2522 Set | 10 MHz to 22 GHz | SMA | 25 dB typ. | 3 dB typ. at 10 GHz | +15 dBm typ. at 10 GHz |
| Photo | Kit | Probes included | Frequency coverage | Choose it for |
|---|---|---|---|---|
![]() |
Y.I.C. NFP Kit | 5 | 10 MHz to 14 GHz | Handheld EMI mapping with five E-field and H-field probes, camera tracking and EMViewer. Uses a compatible external spectrum analyzer. |
![]() |
LF1 set (this set) | 4 | 100 kHz to 50 MHz | Lower-frequency magnetic fields near power circuits |
![]() |
RF Basic set | 6 | 30 MHz to 3 GHz | General PCB survey and fine electric and magnetic troubleshooting |
![]() |
RF1 set | 4 | 30 MHz to 3 GHz | Close-range electric and magnetic troubleshooting |
![]() |
RF2 set | 4 | 30 MHz to 3 GHz | Magnetic survey and source tracing with four heads |
![]() |
RF3 mini set | 2 | 30 MHz to 3 GHz | Sub-millimeter magnetic source localization |
![]() |
RF4-E set | 2 | 30 MHz to 3 GHz | Electric-field coupling and switching-node investigations |
![]() |
XF1 set | 5 | 30 MHz to 6 GHz | Electric and magnetic PCB diagnostics through 6 GHz |
![]() |
SX1 set | 3 | 1 GHz to 10 GHz | Electric and magnetic diagnostics from 1 to 10 GHz |
![]() |
SX-R 20-1 set | 1 | 1 GHz to 20 GHz | Single magnetic probe for measurements through 20 GHz |
![]() |
HR1 set | 2 | Up to 40 GHz | Combined electric and magnetic coverage through 40 GHz |
![]() |
HR-E 40-1 set | 1 | Up to 40 GHz | Single electric-field probe for measurements up to 40 GHz (0.2 mm) |
![]() |
HR-R 8-1 set | 1 | Up to 40 GHz | Single magnetic-field probe for measurements up to 40 GHz |
![]() |
MFA 01 set | 3 | 1 MHz to 6 GHz | Handheld active magnetic microprobes (200 μm) |
![]() |
MFA 02 set | 2 | 1 MHz to 1 GHz | Handheld active magnetic microprobes (200 μm) |