HHS 5215-100 - DC - 6 kHz, Square Helmholtz Coils

Square Helmholtz Coils

Precisely defined magnetic fields. DC - 6 kHz.

The Schwarzbeck HHS 5215-100 generates defined magnetic fields from DC to 6 kHz. Its 100-turn coils provide a calculable relationship between drive current and magnetic field strength.

MARKETS:

TEST STANDARDS:

Data Sheet

SPECIFICATIONS
DC - 6 kHzUsable frequency range
10 AContinuous nominal coil current
100 turnsPer coil
Defined by geometry

A calculable field.
A traceable measurement.

Magnetic field strength is proportional to coil current. Coil geometry, the number of turns and the applied current determine the resulting field, allowing the field measurement to be traced to a current measurement or the voltage drop across a known resistor.

The field depends on coil spacing and the position within the test volume. Use the reference spacings in the specifications and the field distribution data in the datasheet when selecting your setup.

Plan your test setup

Match the field to your application.

Continuous operation

The nominal coil current is 10 A continuous. The specified nominal magnetic field is 842 A/m continuous. Field values apply at the stated reference spacing.

Short-duration operation

The maximum coil current is 20 A (5 min.). Observe the stated time limit and provide adequate ventilation. The frequency range alone does not imply that maximum current or field is available at every frequency.

Technical details

Specifications

Product specifications with reference conditions. See the linked manufacturer datasheet for complete field distributions and operating guidance.

View the complete datasheet →
Number of turns 100
Maximum Coil Current 20 A (5 min.)
Nominal Coil Current 10 A continuous
Max. Magn. Field Strength Approx. 2000 A/m (max. 5 min., coil spacing 0.60 m)
Nominal Magn. Field Strength 842 A/m continuous
Magn. Field Strength, 1 A Coil Current 84.2 A/m (coil dist. 0.84 m*)
Maximum Coil Separation 0.93 m*
Mechanical Dimensions 1.69 m x 1.60 m x 1.00 m
Usable Frequency Range DC - 6 kHz
Inductance (Coil pair) 112 mH
Resonance Frequency (Pair of Coils) >20 kHz
Weight 53 kg
Terminals 4 mm female
Nominal field reference spacing 0.84 m

Where specified, coil distances refer to the coil centers. Continuous and short-duration limits are listed separately. Standards references retain the designations used in the source documents.

Installation and operating safety

Read the supplied datasheet before use. Switch off the complete system before making or removing connections and do not touch terminals during operation. Observe all voltage, current and time limits. High currents heat the coils; maintain adequate air circulation. Keep unintended magnetic field sources and magnetic materials away from the test volume.