HHS 5206-16 - DC - 500 kHz, Circular Helmholtz Coils

  • Circular Helmholtz Coils
  • DC - 500 kHz
  • Diam. 600mm
  • turns 16

MARKETS:

TEST STANDARDS:

Data Sheet

Security Note

SPECIFICATIONS

 

HHS 5206-16 Circular Helmholtz Coils   

Helmholtz-Coils are especially designed to generate precisely defined magnetic fields from DC to the upper end of the audio frequency range and beyond. The generated fields are in a strongly linear relation to the coil current. The fieldstrength can be calculated exactly by analytical (or numerical) methods, based on the coils' geometry, the number of turns and the coil current. Therefore the HHS 5206-16 is ideally suited for the calibration of magnetic field probes or sensors. Due to the high temperature proof Teflon-coated wire packet it is possible to generate magnetic fields up to approx. 2000 A/m (for a short time). Typical applications are magnetic immunity testing according to automotive standards or MIL-461F. When generating magnetic fields with Helmholtz coils the coil current is directly proportional to the magnetic field strength.

 

The calibration of the magnetic field is finally traceable to a current measurement (or to a voltage drop at a known resistor).

 

The Helmholtz-Coils should be installed on a desk in a sufficiently large separation from sources of unintentional magnetic fields, e.g. transformers in power supplies, conductors carrying high currents, computer monitors, loudspeakers, cathode ray tubes (CRT), and more.... All kinds of magnetic material (e.g. steel, Nickel, Cobalt) should be removed from the near surrounding of the coil. The wires which are used to connect the current source with the Helmholtz- Coil should be twisted to avoid an unwanted injection of magnetic flux. The coil terminals are assigned with the characters A, B, C, and D. The generator (current source, audio-amplifier...) is connected to the terminals A and C, the terminals B and D are connected with the short cable supplied with the coil.

Specifications:       

 

  Number of turns: 16
  Maximum Coil Current: 55 A (5 min.)
  Nominal Coil Current: 33 A continuous
  Coil Spacings (centered): 300 mm
  Max. Magn. Field Strength: 2100 A/m (5 min.)
  Nominal Magn. Field Strength: 1260 A/m continuous
  Magn. Field Strength, 1 A Coil Current:

38.17 A/m
151.63 dBµA/m

  Coil Diameter: 600 mm
  Max. Cubical shaped DuT: 32.5 x 32.5 x 32.5 cm
  Mechanical Dimensions: 0.64 m x 0.79 m x 0.42 m
  Terminals: 4 mm female
  Inductance (Single Coil): 340 µH
  Inductance (Coil Pair): 750 µH
  Usable Frequency Range: DC - 500 kHz
  Resonance Frequency: > 700 kHz
 

Weight:

20.4 kg


  