The transient generator CAR-TG 20 is designed according to strict specifications of Ford standards. As per standards FORD FMC1278 and EMC-CS-2009.1 the transient tests defined in RI130, CI220 and CI 260 are generated by CAR-TG20. By that is meant pulse forms: A1, A2-1, A2-2, C-1, C-2, and F.
Therefore, a specified 12VAC Potter & Brumfield relay as well as other parts defined by standard create pulses that are close to real appearing transients.
According to |
|
FORD FMC 1278 | RI130, CI220 |
EMC-CE-2009.1 | RI130, CI220, CI260 |
The transient generator CAR-TG 20 is designed according to strict specifications of Ford standards. As per standards FORD FMC1278 and EMC-CS-2009.1 the transient tests defined in RI130, CI220, and CI 260 are generated by CAR-TG20. By that is meant pulse forms: A1, A2-1, A2-2, C-1, C-2, and F. Therefore, a specified 12VAC Potter & Brumfield relay as well as other parts defined by standard create pulses which are close to real appearing transients.
A microprocessor-controlled 7" touch screen display unit is integrated and permits easy operation of the generator. The following parameters can be selected and varied:
Parameter |
Variations |
Standard routine | RI130, CI220, CI260 |
Mode | M1, M2, M3 |
Pulse form | A1, A1-1, A1-2, C-1, C-2, F |
Test time | 1-1000s, infinity (Standard values predefined) |
Operation | Start / Pause / Stop |
Depending on parameters selected, the internal SW0-SW4 of the standard are switched automatically, its state is also displayed in the screen. Modes M1 (rectangle) and M2, M3 (pseudo-random rectangle) are generated internally.
The CAR-TG 20 offers a battery Input on the left. Outputs for the DUT for pulse A1, A1-1, A1-2, C-1, and F are located on the right side. As well a coaxial bridge can be set between Terminal Pulse C and Sink to define Test CI200 or RI130.
For maintenance reasons, the Potter & Brumfield relay is easy to reach and changeable. Therefore a test time counter on that device is available to detect the end of life of that component. A reset button of that timer is also present.
The CAR-TG 20 excels by its compact design, simple handling, and precise reproducibility of test impulses.
Technical specifications: |
CAR-TG 20 |
|
|
Mainframe |
|
Microprocessor controlled touch panel | 7”, capacitive |
Mains power / BAT-IN | 9V – 56 VDC |
Dimensions, case, W * H * D | 330*115*230 mm3 |
Weight | 8kg |
Technically: |
|
|
|
Resistor R1 | 51Ω, 0,25W |
Resistor R2 | 220Ω, 2W |
Resistor R3 | 33Ω, 10W |
Resisotr R4 | 6Ω, 50W |
Capacitor C1 | 100nF PETP polyester film capacitor, 400V |
Inductor L1 | 5 uH inductor (Osborne transformer #8745) |
Inductor L2 | 100 mH inductor (Osborne transformer #32416) |
Diode D1 | Zener diode, 39V, 5W |
Transistor Q1 | NPN transistor |
Switch SW0-SW4 | Single Throw Switch |
Relay RLY1 | 12 volt AC relay, NC contact used (Potter&Brumfield KUP-14A15-12) |