BOLAB ISO 21498 HV Test System & Ripple Generator

BOLAB ISO 21498 HV Test System & Ripple Generator

CDG 7000 Conducted Immunity, 10 kHz - 400MHz

CDG 7000 Conducted Immunity, 10 kHz - 400MHz

BLS SU 600, Matrix Switching Unit

BLS SU 600, Matrix Switching Unit

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

FIS 100-200 Fast Interrupt Switch 100V/200Amps

FIS 100-200 Fast Interrupt Switch 100V/200Amps

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field

MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field

BOLAB ISO 16750-2 Test System

BOLAB ISO 16750-2 Test System

Products

BOLAB ISO 21498 HV Test System & Ripple Generator

  • Advanced Ripple Testing: Meets ISO 21498, LV123, VW 80300, Nissan MES PW 67602, Mazda, and emerging standards.
  • Series Amplifier Integration: High accuracy ripple injection, minimal distortion, and enhanced safety.
  • Waveform Versatility: Sine, square, trapezoidal, pulses, and triangle waveform generation.
  • WaveMaster Software: Fast DUT impedance measurement, automated test sequences, and dynamic voltage/current control.
  • High Power Capability: Ripple Voltage up to 100 Vpp, currents from 100A to 2000A+, and frequency range 10 Hz–300+ kHz.
  • Future-Proof Design: Modular architecture for easy upgrades and adaptation to new standards.

CDG 7000 Conducted Immunity, 10 kHz - 400MHz

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price.

BLS SU 600, Matrix Switching Unit

  • Protocol reports
  • Generation of waveforms with synchronous data acquisition 
  • Modular Expandable
  • Individual Waveform Generation
  • Standard Libraries included
  • Unlimited Waveform size
  • 2 different Waveforms synchronously 
  • DLL's for LabView, Vector CANoe / CAPL, C#, C++, ANSI C, Python, etc.
  • Simulation of imported oscilloscope waveform

CDG 7000-E Conducted Immunity Generator, (4)9 kHz - 1 GHz , No internal Amplifier

The CDG 7000-E is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. Use an external Amplifier you already have or one that matches your application. 

  • The compact device comprises an RF signal generator, a 3-channel RF voltmeter, and a directional coupler.
  • Frequency range of the generator/power meter (4 kHz): 9 kHz – 1200 MHz
  • The frequency range of the directional coupler: 10 kHz – 1000 MHz, 200 W 
  • Depending on ext. amplifier:  IEC/EN 61000-4-6, IEC 60601-1-2 Ed. 4.1,  IEC 61000-4-39, MIL 461 CS 114, ISO 11452-4, ...

FIS 100-200 Fast Interrupt Switch 100V/200Amps

  • High current power stage (uni-directional)
  • Up to 32 channels for switching low-current signals (bi-directional)
  • Switching of resistive, inductive, capacitive passive, and active loads/devices
  • Input voltage up to 100V
  • Output current up to 200A DC

CDG 7000-75-10 Magnetic & Conducted Immunity, 10 kHz - 250MHz

The CDG 7000 is a new test generator for all standards on immunity to conducted disturbances induced by high-frequency fields - including BCI tests (ISO 11452-4). One of the very few combined IEC 61000-4-6 test systems that contain the RF signal generator, an RF power amplifier, a 3-channel RF voltmeter, and a directional coupler at a very affordable price. IEC 60601-1-2 calling out IEC 61000-4-39 magnetic immunity for close proximity testing requirements can also now be met with the 10 kHz unit. 

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

WaveMaster + AnyWave

BOLAB WaveMaster software and the BOLAB AnyWave control unit allow the control of power supplies as well as 4 quadrant amplifiers via the analog interfaces.

The powerful and easy-to-use BOLAB WaveMaster software is unique in the world. Without any knowledge in software development, designing ordinary and complex waveforms is very easy. A graphic waveform editor allows the generation

of individual curves in no time. Also, with tabular input, all types of waveforms can be produced instantly.

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

WaveMaster + AnyWave

BOLAB WaveMaster software and the BOLAB AnyWave control unit allow the control of power supplies as well as 4 quadrant amplifiers via the analog interfaces.

The powerful and easy-to-use BOLAB WaveMaster software is unique in the world. Without any knowledge in software development, designing ordinary and complex waveforms is very easy. A graphic waveform editor allows the generation

of individual curves in no time. Also, with tabular input, all types of waveforms can be produced instantly.

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

MAG 1000, 120A/m CW, 1100Am Short Duration, Power Frequency Magnetic Field

MAG 1000

  • 1-120A/m Contiunus testing
  • 100-1100A/m Short Duration 1-3sec
  • Test either 50Hz & 60Hz Selectable
  • 1m square Loop

BOLAB ISO 16750-2 Test System

  • DUT Current Ratings: 40A, 76A, 114A, 152A, 190A, 228A
  • Voltage Ripple: Up to 200 kHz (500 kHz)
  • Amplifier: BOLAB 100-TS Series 4-quadrant system
  • Load Dump Generator: BOLAB 10/63-210 1C
  • Switching: FIS 100-xx & FIS SM 96-2 (expandable)
  • Power Supply: BOLAB or third-party compatible
  • High-Voltage & Insulation Testing: G1-1G-T & 90-4K
  • Modular & Scalable: Full ISO 16750-2:2023 compliance

Loading...