CG 10L10100R, 10 kHz - 100MHz, 10/500kHz 10MHz/100MHz Steps, Conducted & Radiated Comb Generator

  • Frequency Range: 
    • 10kHz - 108MHz for AC / DC LISN
    • 10MHz / 100MHz - 7.5GHz for RE
  • Frequency step: 
    • 10/500 kHz switchable for AC / DC LISN
    • 10MHz / 100MHz step switchable for RE
  • Includes: Generator, antenna, charger, wood case

Data Sheet

SPECIFICATIONS

CG 10L10100R, 10 kHz - 7.5GHz, 10/500kHz, 10MHz/100MHz Steps, Conducted & Radiated Comb Generator

Check out our Comb Generator Selection Guide.

Description

CG10L10100R Conducted Comb Generator serves as signal sources for testing Line Impedance Stabilization Networks (LISN) and conducting emissions between 100kHz - 108MHz and radiated measurements within EMI Chambers up to 7.5GHz. With switchable frequency step sizes of 10kHz and 500kHz, they enable thorough checks on conducted measurement systems, such as allowing assessments using LISN and RE standard connectors. The generators' output harmonics align with specified fundamental frequencies based on the chosen step size. Additionally, they feature a rechargeable battery for up to 16 hours of continuous operation and come with a battery charger, USB cable, and accessories in a storage box.

Application

The main purpose of a Comb Generator is to efficiently validate setups for conducted & radiated emissions testing. Its primary application lies in troubleshooting conducted measurements using a LISN and EMI Radiation emission chamber.

With the Comb Generator, the test engineer can conduct frequent and rapid verifications of the conducted test setup, ensuring the reliability of test results.

Additional potential applications of the CG10L10100R Comb Generator may involve the production evaluation of components, such as cable shields and filters, as well as chamber validation in accordance with CISPR16.

Specifications  
Frequency Range 10kHz - 108MHz for AC / DC LISN
10MHz / 100MHz - 7.5GHz for RE
Frequency Step 10 & 500 kHz Switchable for AC/DC LISN
10 & 100 MHz Switchable RE
Power Requirements USB mini,+5Vdc
Output connectors 50-ohm SMA Female
Charging time 8~10 Hours
Usage time 16 Hours
Size 119mm(W)*81.5mm(D)*85.5mm(H)
Net Weight  1kg

 

Field Source Applications

  • normalized site attenuation measurements in fully anechoic rooms (FAR)
  • system checks for test labs (radiated emission)
  • shielding measurements
  • investigation of table and mast influence
  • laboratory inter-comparison measurements
  • test site correlation measurements (same type)
  • correlation of alternative test methods

Comb Generator Applications

  • system checks for test labs (radiated emission)
  • system checks for test labs (conducted emission)
  • “pseudo” EUTs
  • cable loss calibrations
  • normalized site attenuation measurements (SAC)
  • normalized site attenuation measurements (FAR)
  • laboratory inter-comparison measurements
  • test site correlation measurements (same type)
  • correlation of alternative test methods
  • chamber factor measurements
  • investigation of table and mast influence

 

 


 
OTHER PRODUCTS IN THE SAME CATEGORY: