GTEM 1000 – 1100 – 1100F

GTEM 1000 – 1100 – 1100F

GTEM 250 F – GTEM250 F SAE – GTEM FV

GTEM 250 F – GTEM250 F SAE – GTEM FV

GTEM 400 - 450 - 450V

GTEM 400 - 450 - 450V

GTEM 500F – GTEM 550F - GTEM 550VF

GTEM 500F – GTEM 550F - GTEM 550VF

GTEM 750 – 800 – 800F

GTEM 750 – 800 – 800F

TEM-6000 STRIPLINE, 6 GHz IC Testing

TEM-6000 STRIPLINE, 6 GHz IC Testing

Open TEM Cells

Open TEM Cells

TEM Cell (Closed Cell)

TEM Cell (Closed Cell)

DTEM 4000 Double TEM for Shielding effectiveness

DTEM 4000 Double TEM for Shielding effectiveness

GTEM 1250 – 1300

GTEM 1250 – 1300

GTEM 1500 – 1600

GTEM 1500 – 1600

GTEM1750 – 1800

GTEM1750 – 1800

Products

GTEM 1000 – 1100 – 1100F

The GTEMCELL GTEM-1000 Family is a TEM waveguide with the upper-frequency limit extended to the GHz range. It is under consideration as an alternative measurement facility for both radiated emission and immunity measurements. It is included in the standard IEC 61000-4-20 “Emission and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides”.

GTEM 250 F – GTEM250 F SAE – GTEM FV

Model GTEMCELL GTEM250 F with Ferrite tiles on the bottom offers a wider operating bandwidth with peak smoothed and flat response starting from DC to microwave frequencies. It is an indispensable tool for researchers and developers engineers! Model GTEMCELL GTEM250 F SAE includes a special opening to test integrated circuits, dimensions: 80 mm x 80 mm on Approx. 45 mm septum height, closed from a removable panel where are placed the IC under testing.

GTEM 400 - 450 - 450V

The GTEMCELL GTEM 400 family consist of the: GTEM-400 made with 65cm pyramidal carbon-foam absorbers (RAM). GTEM-450 made with 51cm. EMC Truncated pyramidal absorbers (RAM) GTEM-450V is the vertical model (suffix V) made with 51cm. EMC Truncated pyramidal absorbers (RAM)

GTEM 500F – GTEM 550F - GTEM 550VF

GTEM-500 F made with Ferrite tiles on the bottom and 45cm Hybrid pyramidal carbon-foam absorbers (RAM). GTEM-550 F made with Ferrite tiles on the bottom and 35cm Hybrid pyramidal carbon-foam absorbers (RAM). GTEM-550 VF is the vertical model (suffix V) made with Ferrite tiles on the bottom and 35cm Hybrid pyramidal carbon-foam absorbers (RAM).

GTEM 750 – 800 – 800F

The GTEMCELL GTEM-750/800 is a TEM waveguide with the upper-frequency limit extended to the GHz range. It is under consideration as an alternative measurement facility for both radiated emission and immunity measurements. It is included in the standard IEC 61000-4-20 “Emission and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides”.

TEM-6000 STRIPLINE, 6 GHz IC Testing

TEM-6000 STRIPLINE Mod.2020 is a 6 GHz IC Stripline TEM Cell to generate EM fields for testing sample IC devices. It meets the requirements of IEC 61967-2/8, IEC 62132-8 and SAE 1752-3

Open TEM Cells

These Open TEM-cells are well suited for immunity testing of small objects according to European (CE) and automotive standards (SAE J1113-25) or for biological experiments. The advantage of these OTEM cells is that they are open and it is very easy to control the functions of the EUT (Equipment Under Test). The applications are for instance the immunity testing of watches, pagers, telephones or PCB’s.

TEM Cell (Closed Cell)

Transverse ElectroMagnetic (TEM) cell or Crawford cell (named after its inventor) is used to generate accurate electromagnetic waves over a wide frequency range: DC (0 Hz) to GHz. EM waves generated in the cell propagate in transverse mode and have the same characteristics as a plane wave. It can be used to calibrate E-field broadband probes for testing radiated E-field immunity as well as for measuring radiated emission from a product with a spectrum analyzer/EMI receiver.

DTEM 4000 Double TEM for Shielding effectiveness

Double Transverse ElectroMagnetic (DTEM) cell or Double Crawford cell (named after its inventor) is used to generate accurate electromagnetic waves over a wide frequency range: DC (0 Hz) to 4 GHz and measure attenuation through materials in a very predictable and accurate way. EM waves generated in the cell propagate in transverse mode and have the same characteristics as a plane wave. It can be used to calibrate E-field broadband probes for testing radiated E-field immunity as well as for measuring radiated emission from a product with a spectrum analyzer/EMI receiver.

GTEM 1250 – 1300

The GTEMCELL GTEM-1250 Family is a TEM waveguide with the upper-frequency limit extended to the GHz range. It is under consideration as an alternative measurement facility for both radiated emission and immunity measurements. It is included in the standard IEC 61000-4-20 “Emission and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides”.

GTEM 1500 – 1600

The GTEMCELL GTEM-1500 Family is a TEM waveguide with the upper-frequency limit extended to the GHz range. It is under consideration as an alternative measurement facility for both radiated emission and immunity measurements. It is included in the standard IEC 61000-4-20 “Emission and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides”.

GTEM1750 – 1800

The GTEMCELL GTEM-1750 is a TEM waveguide with the upper-frequency limit extended to the GHz range. It is under consideration as an alternative measurement facility for both radiated emission and immunity measurements. It is included in the standard IEC 61000-4-20 “Emission and Immunity Testing in Transverse Electromagnetic (TEM) Waveguides”. Compared to other measuring methods like EMC test in anechoic chambers or OATS (Open Area Test Sites), GTEM-cells offer some significant advantages for the testing of small and medium-sized EUT´s (Equipment Under Test) up to a frequency range of 20 GHz. Quick turn arounds of the EUT, as well as numerous testing variations, are easy and fast to handle. Switching from emission to immunity testing requires only simple adjustments from receiver input to the amplifier output.


Loading...