TBLC08 - 50uH Line Impedance Stabilization Network LISN CISPR 16

TBLC08 - 50uH Line Impedance Stabilization Network LISN CISPR 16

TBOH01 - 5µH Line Impedance Stabilization Network CISPR 25

TBOH01 - 5µH Line Impedance Stabilization Network CISPR 25

TBLM01 - Line Impedance Stabilization Network Mate

TBLM01 - Line Impedance Stabilization Network Mate

TBCDN-M1, CDN, 1-line Power Mains, 15A, 300V AC, 600V DC

TBCDN-M1, CDN, 1-line Power Mains, 15A, 300V AC, 600V DC

TBL5016-2 50µH LINE IMPEDANCE STABILISATION NETWORK LISN – CISPR 16

TBL5016-2 50µH LINE IMPEDANCE STABILISATION NETWORK LISN – CISPR 16

TBL0550-1 5uH 50A Line Impedance Stabilization Network LISN

TBL0550-1 5uH 50A Line Impedance Stabilization Network LISN

TBCDN-M2, CDN, 2-line Power Mains, 36A, 300V AC, 600V DC

TBCDN-M2, CDN, 2-line Power Mains, 36A, 300V AC, 600V DC

TBCDN-M3, CDN, 3-line Power Mains, 36A, 300V AC, 600V DC

TBCDN-M3, CDN, 3-line Power Mains, 36A, 300V AC, 600V DC

TBCDN-M4, CDN, 4-line Power Mains, 36A, 300V AC, 600V DC

TBCDN-M4, CDN, 4-line Power Mains, 36A, 300V AC, 600V DC

TBCDN-M5, CDN, 5-line Power Mains, 36A, 300V AC, 600V DC

TBCDN-M5, CDN, 5-line Power Mains, 36A, 300V AC, 600V DC

TBFL1 - Transient Limiter

TBFL1 - Transient Limiter

TBL5016-1 50uH 16A Line Impedance Stabilization Network LISN

TBL5016-1 50uH 16A Line Impedance Stabilization Network LISN

Products

TBLC08 - 50uH Line Impedance Stabilization Network LISN CISPR 16

The TBLC08 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR16 standard. The device is designed for testing single phase, AC-powered equipment with supply voltages up to maximum 240V.

TBOH01 - 5µH Line Impedance Stabilization Network CISPR 25

The TBOH01 5µH LISN is a device required to setup conducted noise measurements of DC-powered devices. It is designed to be used for EMC pre-testing in the frequency range of 150kHz to 110 MHz.

TBLM01 - Line Impedance Stabilization Network Mate

The TBLM1 LISN Mate is a companion device for LISNs, which splits the conducted noise signal into its common mode and differential mode components. The LISN Mate is connected to the output of a LISN inserted into the positive supply line and to a second LISN inserted into the negative supply line.

TBCDN-M1, CDN, 1-line Power Mains, 15A, 300V AC, 600V DC

The TBCDN-M1 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6. The TBCDN-M1 is compliant with IEC 61000-4-6 Annex D2.

TBL5016-2 50µH LINE IMPEDANCE STABILISATION NETWORK LISN – CISPR 16

The TBL5016-2 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9kHz to 30MHz, according to the CISPR 16-1-2 standard.

The device is designed for testing single phase, AC-powered equipment with supply voltages up to a maximum 240V and 16A.

TBL0550-1 5uH 50A Line Impedance Stabilization Network LISN

The TBL0550-1 5µH LISN is a device required to setup conducted noise measurements of DC-powered electronic equipment. It is designed to be used for measurements in the frequency range of 150kHz to 110 MHz according to CISPR 16-1-2, CISPR-25, EN55025, MIL-STD-461F, ISO11452-4 and with limitations DO-160/ED-14G and ISO 7637-2.

TBCDN-M2, CDN, 2-line Power Mains, 36A, 300V AC, 600V DC

The TBCDN-M2 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6. The TBCDN-M2 is compliant with IEC 61000-4-6 Annex D2.

TBCDN-M3, CDN, 3-line Power Mains, 36A, 300V AC, 600V DC

The TBCDN-M3 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6.

TBCDN-M4, CDN, 4-line Power Mains, 36A, 300V AC, 600V DC

The TBCDN-M4 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6.

TBCDN-M5, CDN, 5-line Power Mains, 36A, 300V AC, 600V DC

The TBCDN-M5 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6.

TBFL1 - Transient Limiter

The TBFL1 is a combined transient limiter/attenuator/ high pass filter, designed to provide optimum protection of spectrum analyzer or measurement receiver inputs when carrying out conducted noise measurements or other measurements where the input levels cannot be predicted with certainty or where accidental overloads may occur.

TBL5016-1 50uH 16A Line Impedance Stabilization Network LISN

The TBL5016-1 50µH LISN is a device required to setup conducted noise measurements of DC or AC-powered electronic equipment. It is designed according to CISPR 16-1-2 and MIL-STD-461F standard and characterized in the frequency range of 9kHz to 100 MHz.


Loading...