PG 20 - 4000, High Voltage Pulse Generator, 10/700µs, 5/320µs, 20kV

PG 20 - 4000, High Voltage Pulse Generator, 10/700µs, 5/320µs, 20kV

AC-Tester 6, 10 kV Alternating voltage, Isolation testing set

AC-Tester 6, 10 kV Alternating voltage, Isolation testing set

IPG 506: FRONT-CHOPPED-WAVE GENERATOR

IPG 506: FRONT-CHOPPED-WAVE GENERATOR

PG 6 250: VARISTOR TESTER

PG 6 250: VARISTOR TESTER

PG 6-364: HV Pulse Generator

PG 6-364: HV Pulse Generator

PG 10-504: 10kV Surge CWG

PG 10-504: 10kV Surge CWG

PG 12-804  12kV Surge CWG

PG 12-804 12kV Surge CWG

PG 24 - 2500 Surge Test Generator

PG 24 - 2500 Surge Test Generator

IPG 506 SYM: FRONT-CHOPPED-WAVE, 3-Pole DUT

IPG 506 SYM: FRONT-CHOPPED-WAVE, 3-Pole DUT

IPG 809, Capacitor Tester, 8kV

IPG 809, Capacitor Tester, 8kV

PG 10-150, Flammability test, 10kV

PG 10-150, Flammability test, 10kV

PG 10-200 / PG 12-360, Solar modules test, 10kV & 12kV

PG 10-200 / PG 12-360, Solar modules test, 10kV & 12kV

Products

PG 20 - 4000, High Voltage Pulse Generator, 10/700µs, 5/320µs, 20kV

The high-voltage impulse generator PG 20-4000 generates standard impulse voltages with waveform 10/700 µs. The output voltage is adjustable between 1 kV and 20 kV. The polarity of the output voltage is selectable, positive or negative.

AC-Tester 6, 10 kV Alternating voltage, Isolation testing set

The alternating voltage testing set ACT ESTER 6 is suitable for the execution of the high- voltage test from isolations to VDE 0113, VDE 0700 part of 500, VDE of 0551 etc. IEC 60335, IEC 60204, IEC 60598, IEC 60745 The device essentially consists of a regulating transformer with a motor drive, a high voltage transformer, and a control unit. The output voltage can be adjusted by 0 - 10 kV.

IPG 506: FRONT-CHOPPED-WAVE GENERATOR

The front-chopped-wave generator IPG 506 is used for measuring dc spark-over voltage and impulse spark-over voltage of over-voltage protectors according to CCITT / ITU-T, K12. Dc spark-over voltage: A linearly rising voltage, rate of rise 100 V/s up to 640 V, is connected to the device under test. The spark-over voltage measured is shown in the display. Impulse spark-over voltage: A linearly rising impulse voltage, rate of rise 100 V/µs up to 5000 V/µs, open loop amplitude 5000 V, is connected to the device under test. The spark-over voltage is measured by use of a peak detector. The result is shown in the display. A built-in impulse voltage divider allows measurement of the spark-over voltage by use of an externally connected scope. Picture: incl. Option PA 503

PG 6 250: VARISTOR TESTER

The VARISTOR-TESTER PG 6-250 is a compact test generator for testing the surge current capability of varistors. The unit contains a combination wave generator and a surge voltage generator acc. to CCITT, ITU-T.

PG 6-364: HV Pulse Generator

The high-voltage impulse generator PG 6-364 generates standard impulse voltages with waveforms 1.2/50 µs and 10/700 µs. The Output voltage is adjustable between 0.2 kV and 6 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected. The generator is designed for dielectric testing of components and systems as well as testing of the electromagnetic compatibility of electronic systems and devices acc. to CCITT K17/K20/K22, ITU-T/K44, IEC 61000-4-5, VDE 0847.

PG 10-504: 10kV Surge CWG

The Combination Wave Generator PG 10-504 is a combined impulse-current-/impulse-voltage generator which, for high-impedance loads, RL > 100?, delivers a standard impulse voltage with waveform 1.2/50µs and, for short-circuited output, a standard impulse current with waveform 8/20µs. The generator allows surge testing of components and devices, the galvanic coupling of surges to cable shields, shielded enclosures and cabinets as well as testing electromagnetic compatibility, EMC, of electronic devices and systems against pulsed and conducted interference.

PG 12-804 12kV Surge CWG

The Combination Wave Generator PG 12-804 is a combined impulse-current-/impulse-voltage generator which, for high-impedance loads, RL > 100?, delivers a standard impulse voltage with waveform 1.2/50µs and, for short-circuited output, a standard impulse current with waveform 8/20µs. The generator allows surge testing of components and devices, galvanic coupling of surges to cable shields, shielded enclosures and cabinets as well as testing electromagnetic compatibility, EMC, of electronic devices and systems against pulsed and conducted interference.

PG 24 - 2500 Surge Test Generator

The Surge Test Generator PG 24-2500 is a combined impulse current-/impulse-voltage generator which, for high-impedance loads, RL > 100?, delivers a standard impulse voltage with waveform 1.2/50µs and, for short-circuited output, a standard impulse current with waveform 8/20µs, as defined by IEC 60. The peak value of the pulse output voltage can be adjusted from 0.5 kV to 24 kV. The peak short circuit current amplitude is 12 kA.

IPG 506 SYM: FRONT-CHOPPED-WAVE, 3-Pole DUT

The front-chopped-wave generator IPG 506 is used for measuring dc spark-over voltage and impulse spark-over voltage of over-voltage protectors according to CCITT / ITU-T, K12. DC spark-over voltage: A linearly rising voltage, rate of rise 100 V/s up to 640 V, simultaneous plus and minus, is connected to the device under test. The spark-over voltage of these two simultaneous impulses is measured and shown in the display. Impulse spark-over voltage: A linearly rising impulse voltage, simultaneous plus, and minus, rate of rise 100 V/µs up to 5000 V/µs, open loop amplitude 5000 V, is connected to the device under test. The spark-over voltage is measured by use of a peak detector. The results of these two simultaneous impulses are shown on the display. The picture is shown with PA 503 Option.

IPG 809, Capacitor Tester, 8kV

The High-Voltage Pulse Generator Type IPG 809 is designed for dielectric testing of X- and Y-capacitors with standard impulse voltages 1.7/46 µs –0/+50% up to 8 kV acc. to IEC 60384-14, EN 132400, VDE 0565 etc. Picture: incl. Option PA 503

PG 10-150, Flammability test, 10kV

The PG 10-150 consists essentially of a variable transformer with motor drive, isolating transformer, filter circuit, DUT with parallel capacitor and a high-voltage pulse generator. All settings in the power section are made on the control unit. The pulse-forming networks according to IEC 60384-14 are adjustable.

PG 10-200 / PG 12-360, Solar modules test, 10kV & 12kV

The HV-Pulse generator PG10-200 / PG12-360 is used for impulse voltage tests of solar modules (photovoltaic panels) with the standard surge voltage waveform 1.2/50 µs according to IEC 60060-1/2 up to 10 kV acc. to. IEC 61730-1/2 / EN 61730-1. For the surge voltage tests of solar modules, these are enveloped with a copper foil as described in the relative above standard. After that the connections of the solar modules are tested with surge voltage against the copper foils. The tight copper foil envelope required by the standard results in comparatively high capacitances of approx. 0 - 183 nF, which is switched in parallel to the output of the impulse generator.