VBA2000P Series — 1 to 2 GHz Class-AB Pulse RF Power Amplifiers

VBA2000P Series — 1 to 2 GHz Class-AB Pulse RF Power Amplifiers

VBA400 Series — 10 kHz to 400 MHz Class-A RF Power Amplifiers

VBA400 Series — 10 kHz to 400 MHz Class-A RF Power Amplifiers

VBA1000 Series — 80 to 1000 MHz Class-A RF Power Amplifiers

VBA1000 Series — 80 to 1000 MHz Class-A RF Power Amplifiers

VBA1060 Series — 1 to 6 GHz Class-A RF Power Amplifiers

VBA1060 Series — 1 to 6 GHz Class-A RF Power Amplifiers

VBA250 Series — 10 kHz to 250 MHz Class-A RF Power Amplifiers

VBA250 Series — 10 kHz to 250 MHz Class-A RF Power Amplifiers

VBA100 Series — 10 kHz to 100 MHz Class-A RF Power Amplifiers

VBA100 Series — 10 kHz to 100 MHz Class-A RF Power Amplifiers

VBA1032-450 — 1 to 3.2 GHz, 450Watts, Class-A RF Power Amplifiers

VBA1032-450 — 1 to 3.2 GHz, 450Watts, Class-A RF Power Amplifiers

VBA230 Series — 150 kHz to 230 MHz Class-A RF Power Amplifiers

VBA230 Series — 150 kHz to 230 MHz Class-A RF Power Amplifiers

VBA200-3000 — 12 MHz to 200 MHz, 3kW, Class-A RF Power Amplifiers

VBA200-3000 — 12 MHz to 200 MHz, 3kW, Class-A RF Power Amplifiers

VBA0742 Series — 0.7 to 4.2 GHz Class-A RF Power Amplifiers

VBA0742 Series — 0.7 to 4.2 GHz Class-A RF Power Amplifiers

VBA2060 Series — 2 to 6 GHz Class-A RF Power Amplifiers

VBA2060 Series — 2 to 6 GHz Class-A RF Power Amplifiers

VBA0860 Series — 0.8 to 6 GHz Class-A RF Power Amplifiers

VBA0860 Series — 0.8 to 6 GHz Class-A RF Power Amplifiers

Products

VBA2000P Series — 1 to 2 GHz Class-AB Pulse RF Power Amplifiers

  • Class-A architecture 
  • High reliability proven GaAs design
  • Wideband 1 GHz – 2 GHz 
  • Unconditional stability & extreme VSWR tolerance 
  • RTCA DO-160 Section 20 testing

VBA400 Series — 10 kHz to 400 MHz Class-A RF Power Amplifiers

  • Class-A architecture 
  • Push-pull MOSFET output
  • Wideband 10 kHz–400 MHz 
  • Unconditional stability & extreme VSWR tolerance 
  • Integrated digital interfaces (select models)

VBA1000 Series — 80 to 1000 MHz Class-A RF Power Amplifiers

  • Class-A architecture 
  • Push-pull LDMOS output
  • Wideband 80 MHz–1000 MHz 
  • Unconditional stability & extreme VSWR tolerance 
  • Integrated digital interfaces (select models)

VBA1060 Series — 1 to 6 GHz Class-A RF Power Amplifiers

  • Class-A architecture 
  • GaN Quadrature Hybrid
  • Wideband 1 GHz – 6 GHz 
  • Unconditional stability & extreme VSWR tolerance 
  • Integrated digital interfaces (select models)

VBA250 Series — 10 kHz to 250 MHz Class-A RF Power Amplifiers

  • Class-A architecture 
  • Push-pull MOSFET output
  • Wideband 10 kHz–250 MHz 
  • Unconditional stability & extreme VSWR tolerance 
  • Integrated digital interfaces (select models)

VBA100 Series — 10 kHz to 100 MHz Class-A RF Power Amplifiers

  • Class-A operation for ultra-low distortion and predictable linear performance
  • 100% mismatch tolerance with no fold-back protection required
  • Push-pull MOSFET output stages for harmonic suppression and ruggedness
  • Wide instantaneous bandwidth from 10 kHz to 100 MHz
  • High-efficiency proprietary combiners for scalable power levels
  • Designed for EMC test environments, chambers, and transducer drive
  • Integrated digital interfaces (select models)

VBA1032-450 — 1 to 3.2 GHz, 450Watts, Class-A RF Power Amplifiers

  • GaN technology with extra-wideband output stages 
  • Class-A operation for low distortion and robust mismatch drive
  • Unconditional stability and infinite VSWR tolerance (within permitted excitation limits)
  • Remote control: Ethernet / USB / GPIB 
  • Interlocks and monitoring: power levels, interlock states, PSU health; forward/reflected sample ports 

VBA230 Series — 150 kHz to 230 MHz Class-A RF Power Amplifiers

  • Class-A operation for low distortion and highly linear RF output
  • 100% mismatch tolerant (Infinity:1 VSWR) with no fold-back protection required
  • Push-pull MOSFET architecture for even-order harmonic suppression
  • Wide instantaneous bandwidth from 150 kHz to 230 MHz
  • Compact rack or bench configurations for lab and chamber use
  • Designed for continuous EMC testing environments

VBA200-3000 — 12 MHz to 200 MHz, 3kW, Class-A RF Power Amplifiers

  • Class-A operation for low distortion and highly linear RF output
  • 100% mismatch tolerant (Infinity:1 VSWR) with no fold-back protection required
  • Push-pull MOSFET architecture for even-order harmonic suppression
  • Wide instantaneous bandwidth from 12 to 200 MHz
  • Compact rack or bench configurations for lab and chamber use
  • Designed for continuous EMC testing environments

VBA0742 Series — 0.7 to 4.2 GHz Class-A RF Power Amplifiers

  • Class-A architecture 
  • GaN Quadrature Hybrid
  • Wideband 700 MHz – 4.2 GHz 
  • Unconditional stability & extreme VSWR tolerance 
  • Integrated digital interfaces (select models)

VBA2060 Series — 2 to 6 GHz Class-A RF Power Amplifiers

  • Class-A architecture 
  • GaN Quadrature Hybrid
  • Wideband 2 – 6 GHz 
  • Unconditional stability & extreme VSWR tolerance 
  • Integrated digital interfaces (select models)

VBA0860 Series — 0.8 to 6 GHz Class-A RF Power Amplifiers

  • Class-A architecture 
  • GaN Quadrature Hybrid
  • Wideband 800 MHz – 6 GHz 
  • Unconditional stability & extreme VSWR tolerance 
  • Integrated digital interfaces (select models)