305-AC, 0-305V, 30->1050kVA, AC Power Supply

305-AC, 0-305V, 30->1050kVA, AC Power Supply

ESD Test Table Kit

ESD Test Table Kit

EFTC-CK  Calibration kit for burst coupling clamps

EFTC-CK Calibration kit for burst coupling clamps

PFS-CE-16: Dips/Drops/Variations

PFS-CE-16: Dips/Drops/Variations

EFTG-CE5: 5kV, EFT 5/50ns, 1-1000 kHz

EFTG-CE5: 5kV, EFT 5/50ns, 1-1000 kHz

CWG-CE5: 5kV Surge,  1.2/50µs Voltage, 8/20µs Current

CWG-CE5: 5kV Surge, 1.2/50µs Voltage, 8/20µs Current

CWG-CE7  7kV SURGE, 1.2/50µs VOLTAGE, 8/20µs CURRENT

CWG-CE7 7kV SURGE, 1.2/50µs VOLTAGE, 8/20µs CURRENT

BCK 400 F  Calibration kit for EFT/burst Generators

BCK 400 F Calibration kit for EFT/burst Generators

IMP 8, Impedance matching network for IEC 61000-4-5

IMP 8, Impedance matching network for IEC 61000-4-5

SCK 105, Surge Calibration Kit

SCK 105, Surge Calibration Kit

SCK 105 inBox, Surge Calibration Kit

SCK 105 inBox, Surge Calibration Kit

VPS 250, Automatic Variack 0-250V 16Amps

VPS 250, Automatic Variack 0-250V 16Amps

Products

305-AC, 0-305V, 30->1050kVA, AC Power Supply

    • Technologically advanced, fast-switching, compact 19-inch power supplies
    • High control dynamics in the 100...200 µs range – even at higher power levels
    • Exceptional current accuracy of <0.02% FS, additional high-resolution current measurement range included as standard
    • Full power regeneration and a high degree of efficiency, resulting in a significant reduction of energy consumption and heat dissipation, low acoustic noise
    • Wide current-voltage range with an auto-ranging factor of 3
    • Full digital CV, CC, CP, CR, and Ri-Sim control modes

 

ESD Test Table Kit

The ESD Test Table Kit is a simple inexpensive solution for your ESD testing. Complies to the requirements of IEC 61000-4-2 and can be used for additional standards. Comes with a Horizontal Coupling Plane (HCP), resistive cable to tie HCP to floor ground plane, bleeder wire for discharging ungrounded battery powered EUTs, 0.05mm insulator and an alternative low impedance ground for using the table for additional setups such as IEC 61000-4-6 requirements.

EFTC-CK Calibration kit for burst coupling clamps

The EFTC-CK is a calibration kit for burst/EFT coupling clamps as specified in IEC 6100-4-4:2012. It has been designed for calibration of coupling clamps like EFTC2012. The set consists of a transducer plate and a termination bracket (connecting adapter).

PFS-CE-16: Dips/Drops/Variations

The Power Fail Simulator PFS-CE-16 is a compact EMC test unit designed for testing electromagnetic immunity against interruption and variation of the power supply voltage acc. to IEC 61000-4-11. Demonstrating such immunity is generally a requirement of the European EMC directive, a necessary step leading to the final attachment of the CE mark.

EFTG-CE5: 5kV, EFT 5/50ns, 1-1000 kHz

The Electrical Fast Transient Generator EFTG-CE5 is a compact EMC test unit for testing electromagnetic immunity against electrical fast transients. The generator provides burst-pulses, which are adjustable in frequency, amplitude, duration and repetition rate. It is suitable to test the susceptibility levels of electrical systems and installations full compliant to IEC 61000-4-4.

CWG-CE5: 5kV Surge, 1.2/50µs Voltage, 8/20µs Current

The CWG-CE5 is a compact EMC test unit designed for testing electromagnetic immunity against pulsed and conducted interference. Demonstrating such immunity is generally a requirement for compliance with the European EMC directive, a necessary step leading to the CE mark.

CWG-CE7 7kV SURGE, 1.2/50µs VOLTAGE, 8/20µs CURRENT

The Combination Wave Generator CWG-CE7 is a combined impulse-current-/impulse-voltage generator which, for high-impedance loads, RL > 100?, delivers a standard impulse voltage with waveform 1.2/50?s and, for short-circuited output, a standard impulse current with waveform 8/20?s.

BCK 400 F Calibration kit for EFT/burst Generators

The Burst Calibration Kit has been designed to measure the pulse output voltage and the pulse output current of burst generators, e.g. the EFTG-CE5 or the burst generator sub-unit of the Multi-CE5. It essentially consists of a load resistor, a pulse voltage divider, and a double-shielded coaxial cable. ? Burst Calibration Kit ? Input voltage: 5 kV ? Ratio, 200/400:1 ? Bandwidth: 400 MHz

IMP 8, Impedance matching network for IEC 61000-4-5

The external impedance IMP8 is the impedance, required for the pulse specifications according to standard IEC 61000-4-5 Ed.3, for measuring the pulse output voltage of surge generators.

SCK 105, Surge Calibration Kit

The Surge Calibration Kit has been designed to measure the pulse output voltage and the pulse output current of surge generators, e.g. a combination wave generator. It essentially consists of a pulse voltage divider, a pulse current measuring resistor, and a double-shielded coaxial cable.

SCK 105 inBox, Surge Calibration Kit

The Surge Calibration Kit has been designed to measure the pulse output voltage and the pulse output current of surge generators, e.g. a combination wave generator. It essentially consists of a pulse voltage divider, a pulse current measuring resistor, and a double-shielded coaxial cable. The unit is easy to connect and use for everyday pulse verification.

VPS 250, Automatic Variack 0-250V 16Amps

Motor-driven variable transformer, controlled by Multi-CE5 or Multi-CE7, used for power supply variation acc. to IEC 61000-4-11 and setting current for IEC 61000-4-8 Magnetic fields

Loading...