CAR CDN 2012 EFT/Burst Capacitive Coupling Clamp ISO

CAR CDN 2012 EFT/Burst Capacitive Coupling Clamp ISO

CAR Cal Kit, Standard loads for Automotive Testing

CAR Cal Kit, Standard loads for Automotive Testing

Emergency stop

Emergency stop

Foot-switch Trigger

Foot-switch Trigger

Warning light

Warning light

CURRENT-VIEWING RESISTORS WSM Type

CURRENT-VIEWING RESISTORS WSM Type

CURRENT-VIEWING RESISTORS ISM Type

CURRENT-VIEWING RESISTORS ISM Type

HVM 2015 High Voltage Meter 10kV, 20kV, ext. HVT 300kV

HVM 2015 High Voltage Meter 10kV, 20kV, ext. HVT 300kV

HVT-RCR Broadband high voltage dividers

HVT-RCR Broadband high voltage dividers

EFTC-CK  Calibration kit for burst coupling clamps

EFTC-CK Calibration kit for burst coupling clamps

BCK 400 F  Calibration kit for EFT/burst Generators

BCK 400 F Calibration kit for EFT/burst Generators

IMP 8, Impedance matching network for IEC 61000-4-5

IMP 8, Impedance matching network for IEC 61000-4-5

Products

CAR CDN 2012 EFT/Burst Capacitive Coupling Clamp ISO

The coupling clamp CDN 2012 conforms exactly to the requirements of ISO 7637-3 and other standards, guaranteeing that tests are carried out in strict compliance with the standard. The CDN allows the fast nanosecond pulse bursts ( ISO 3a and 3b) to be injected in cable runs. Very high impedance signal lines are also to be found in vehicles on which the disruptive effects of ISO pulses 1 and 2 can also show up through capacitive coupling.

CAR Cal Kit, Standard loads for Automotive Testing

In accordance with the pulse verification requirements given in Annex C of ISO 7637-2:2011 and Annex A of ISO 16750-2:2012, test pulses generated by automotive transient generators need to be verified both under no-load (open circuit verification) and loaded conditions with specified loads.

Emergency stop

Emergency stop switch for interrupting / close the internal safety circuits.

Foot-switch Trigger

Footswitch to trigger certain generator functions.

Warning light

Warning / signal lamps for visualizing the generator state. Signal red: "Warning Hazard", signal green: "all clear".

CURRENT-VIEWING RESISTORS WSM Type

WSM-type AC/DC current-Viewing resistors are designed for precise measurement of pulsed ac- and dc currents, for instance in industrial drives, pulsed welders and plasma physics apparatuses. Moreover, they are employed in short-circuit test facilities, measurement of start currents of fuel engines etc.

CURRENT-VIEWING RESISTORS ISM Type

Current-viewing-resistors Series ISM allows precise measurement of peak value and waveform of fast rise time current pulses. They excel by high bandwidth, low rise time and high accuracy of resistance value. Below their upper-frequency limit (-3 dB), the current-viewing-resistors ISM behave like pure dc resistors with frequency-independent resistance value. Because of their double coaxial design current-viewing-resistors, ISM are not susceptible to noise and electromagnetic interference.

HVM 2015 High Voltage Meter 10kV, 20kV, ext. HVT 300kV

The high-voltage measurement instruments HVM 2015 consist of a measuring amplifier for universal use with a digital touch display, a built-in high-voltage divider for direct measurement up to 10 kV / optional 20 kV and an external input for an external high-voltage divider, HVT***RCR, measurement, and display of voltages up to 300 kV. The HVM 2015 is designed for measuring ac- and dc- voltages and allows in addition measurement of the peak value of lightning and switching pulse voltages.

HVT-RCR Broadband high voltage dividers

The Broadband high-voltage dividers series HVT...RCR are state-of-the-art measuring equipment with excellent high-frequency transmission characteristics. The high-voltage impedance consists of a precise metal film resistor and a high-voltage capacitor with a series damping resistor in parallel. The measuring cable with the termination network is an essential part of the divider. The termination network can be adjusted for an oscilloscope input impedance of 1 M? // 10 - 30 pF.

EFTC-CK Calibration kit for burst coupling clamps

The EFTC-CK is a calibration kit for burst/EFT coupling clamps as specified in IEC 6100-4-4:2012. It has been designed for calibration of coupling clamps like EFTC2012. The set consists of a transducer plate and a termination bracket (connecting adapter).

BCK 400 F Calibration kit for EFT/burst Generators

The Burst Calibration Kit has been designed to measure the pulse output voltage and the pulse output current of burst generators, e.g. the EFTG-CE5 or the burst generator sub-unit of the Multi-CE5. It essentially consists of a load resistor, a pulse voltage divider, and a double-shielded coaxial cable. ? Burst Calibration Kit ? Input voltage: 5 kV ? Ratio, 200/400:1 ? Bandwidth: 400 MHz

IMP 8, Impedance matching network for IEC 61000-4-5

The external impedance IMP8 is the impedance, required for the pulse specifications according to standard IEC 61000-4-5 Ed.3, for measuring the pulse output voltage of surge generators.