CATAGORY

305-AC, 0-305V, 30->1050kVA, AC Power Supply

305-AC, 0-305V, 30->1050kVA, AC Power Supply

Injection Clamp Kits (ICK) EM and BCI Clamps

Injection Clamp Kits (ICK) EM and BCI Clamps

CDN EMCL-20 / CDN EMCL-35 EM Clamp

CDN EMCL-20 / CDN EMCL-35 EM Clamp

CDN ABCL-20 Decoupling Clamp

CDN ABCL-20 Decoupling Clamp

EMCL- NW 10 / MN-1 EM Clamp Matching Network

EMCL- NW 10 / MN-1 EM Clamp Matching Network

CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

Products

305-AC, 0-305V, 30->1050kVA, AC Power Supply

    • Technologically advanced, fast-switching, compact 19-inch power supplies
    • High control dynamics in the 100...200 µs range – even at higher power levels
    • Exceptional current accuracy of <0.02% FS, additional high-resolution current measurement range included as standard
    • Full power regeneration and a high degree of efficiency, resulting in a significant reduction of energy consumption and heat dissipation, low acoustic noise
    • Wide current-voltage range with an auto-ranging factor of 3
    • Full digital CV, CC, CP, CR, and Ri-Sim control modes

 

Injection Clamp Kits (ICK) EM and BCI Clamps

Absolute EMC offers an assortment of injection test kits for the use of conducted immunity. The kits can be used with many available conducted immunity systems, including the Schlöder CDG 7000, to make selection and setup easy. All calibration fixtures, injection clamps, attenuators, and termination resistors necessary for meeting the requirements of conducted immunity systems. All all-in-one systems are covered. 

CDN EMCL-20 / CDN EMCL-35 EM Clamp

EM Clamp for immunity tests IEC / EN 61000-4-6 Ed. 4.0 • EM Clamp for immunity testing of cables with up to 20 (35) mm diameter • High coupling factor: less than 15 watts amplifier output power is required to obtain a test level of 10 V • Calibration unit and calibration data are supplied with each unit.

CDN ABCL-20 Decoupling Clamp

CDN ABCL-20 Decoupling Clamp for immunity according to IEC / EN 61000-4-6 Ed. 4.0 100 kHz – 1000 MHz Features: For additional decoupling at immunity testing according to IEC / EN 61000-4-6 Suitable for cables up to 20mm diameter

EMCL- NW 10 / MN-1 EM Clamp Matching Network

EMCL- NW 10 / MN-1 Matching Network • For use with the EMCL-20 in the frequency range 10 kHz – 150 kHz • For use with the CDN BCI-P1 in the frequency range 10 kHz – 150 kHz

CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

BCI-P1 Bulk Current Injection Probe 10 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005 and IEC 61000-4-6 - Frequency range from 1 MHz up to 400 MHz - Designed for automotive BCI testing - Low insertion loss (1MHz - 400MHz) to test bellow 1MHz (IEC/DO/MIL) see CDN BCI-P1_MT-1

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005, MIL-STD-461, DO-160 and IEC 61000-4-6 - Frequency range from 4 kHz up to 400 MHz - Designed for BCI testing 

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

CDG CMP-45 Current monitoring probe • Cable diameters up to 45 mm • Frequency range 10 kHz to 400 MHz • Foldable, easy positioning on the conductor / cable • For BCI testing acc. to ISO 11452-4 and others • Insertion impedance < 2,5 ?


Loading...