TBAS2 SMA Attenuator & Terminatation Set

TBAS2 SMA Attenuator & Terminatation Set

TBPS01 EMC NEAR-FIELD PROBES

TBPS01 EMC NEAR-FIELD PROBES

TBMR-110M DC - 110 MHz high speed EMI-Analyzer

TBMR-110M DC - 110 MHz high speed EMI-Analyzer

TBCG2 Comb Generator/Frequency Multiplier

TBCG2 Comb Generator/Frequency Multiplier

TBCG3-RN2 Comb Generator, 5 kHz-2 GHz, for RE

TBCG3-RN2 Comb Generator, 5 kHz-2 GHz, for RE

TBCG3-RN6 Comb Generator, 5 kHz-6 GHz, for RE

TBCG3-RN6 Comb Generator, 5 kHz-6 GHz, for RE

TBCCP1-400K600 COAXIAL RF CURRENT MONITORING PROBE

TBCCP1-400K600 COAXIAL RF CURRENT MONITORING PROBE

Probe Stand

Probe Stand

CISPR 17 Equipment

CISPR 17 Equipment

BN 1701, Buffer network

BN 1701, Buffer network

TBCG3-CN Comb Generator, 5 kHz-2 GHz, for CE

TBCG3-CN Comb Generator, 5 kHz-2 GHz, for CE

TBCCP1-2K70 COAXIAL RF CURRENT MONITORING PROBE

TBCCP1-2K70 COAXIAL RF CURRENT MONITORING PROBE

Products

TBAS2 SMA Attenuator & Terminatation Set

The TBAS2 RF SMA attenuator/termination set consists of a 3dB, 6dB, 10dB, 15dB, 20dB and 30dB SMA attenuators in a beechwood box. Furthermore, it contains two pieces SMA 50 Ohm terminations.

TBPS01 EMC NEAR-FIELD PROBES

The H20, H10, H5, and E5 are magnetic field (H) and electric field (E) probes for radiated emissions EMC pre-compliance measurements. The probes are used in the near field of sources of electromagnetic radiation. They serve to locate and identify potential sources of interference within the building blocks of electronic assemblies. The probes act similar to wide bandwidth antennas, picking up radiated emissions from components, PCB traces, housing openings or gaps, and from any other parts that could be emitting RF. The probes are usually connected to a spectrum analyzer. Scanning the probe over the surface of a PCB assembly or housing quickly identifies locations that emit electromagnetic radiation. By changing to a probe with a smaller size, the origination of the emissions can be further narrowed down. 

TBMR-110M DC - 110 MHz high speed EMI-Analyzer

The TBMR-110M EMI Analyzer is designed to carry out conducted emission measurements. Its affordability and versatility make it a perfect tool for engineers doing pre-compliance measurements during the development process.
  • True DC – 110 MHz measurement range
  • CISPR-16, ANSI and MIL-STD compliant detectors
  • Peak, Quasi-Peak, Average, CISPR Average, RMS and CISPR RMS dectectors working in parallel
  • Zero Span operation with time domain triggering
  • Linear, log amplitude and frequency display

TBCG2 Comb Generator/Frequency Multiplier

The TBCG2 is a passive, step recovery diode based comb generator/frequency multiplier. It is optimized for moderate drive power and spectrum flatness in the frequency range 1 MHz to 2.5GHz. The recommended drive power is +10 dBm to +20 dBm The frequency range for the drive signal is 1 MHz to 350MHz

TBCG3-RN2 Comb Generator, 5 kHz-2 GHz, for RE

The TBCG3-RN2 comb generator is primarily intended for testing radiated emission setups. It is a useful tool for validating the proper operation of the antenna and pre-amplifier, as well as the accurate set-up and configuration of the spectrum analyzer.

  • 5 kHz-2 GHz,
  • switchable 5, 10, 25, 50, 100 MHz,
  • external: 5 kHz-200 MHz,
  • 6xNiMH, AA, Charger,
  • 2 monopole antennas

TBCG3-RN6 Comb Generator, 5 kHz-6 GHz, for RE

The TBCG3-RN6 comb generator is primarily intended for testing radiated emission setups. It is a useful tool for validating the proper operation of the antenna and pre-amplifier, as well as the accurate set-up and configuration of the spectrum analyzer.

  • 5 kHz-6 GHz,
  • switchable 5, 10, 25, 50, 100 MHz,
  • external: 5 kHz-200 MHz,
  • 6xNiMH, AA, Charger,
  • 2 monopole antennas

TBCCP1-400K600 COAXIAL RF CURRENT MONITORING PROBE

The TBCCP1-400K600 is a coaxial RF current monitoring probe with a 3 dB bandwidth from 400 kHz to 600 MHz and a very flat response from 1 MHz to 200 MHz. 

Probe Stand

Our custom-designed probe stand is ideal for mounting radiated immunity probes, sound probes, and small cameras.

CISPR 17 Equipment

Transformers

fixtures and adapters to measure filters

ferrites and other passive components.

Detailed product list and data sheets on request.

BN 1701, Buffer network

Buffer network  (CISPR 17)

Frequency range: 100 kHz - 30 MHz

max. 32 A

TBCG3-CN Comb Generator, 5 kHz-2 GHz, for CE

The TBCG3-CN comb generator is primarily designed to verify conducted emission test setups. It is a useful tool to validate the correct operation of the LISN, correct set-up, and correct configuration of the spectrum analyzer.

  • 5 kHz-2 GHz,
  • switchable 0.1, 0.5, 1, 5, 10 MHz,
  • external: 5 kHz-300 MHz,
  • 4xNiMH, AA, Charger,
  • Country-specific adapter cables DUT socket of the LISN

TBCCP1-2K70 COAXIAL RF CURRENT MONITORING PROBE

The TBCCP1-2K70 is a coaxial RF current monitoring probe with a very flat response from 2 kHz to 70 MHz and is characterized over the frequency range from 10 Hz to 100 MHz. 

Loading...