FIS 100-200 Fast Interrupt Switch 100V/200Amps

FIS 100-200 Fast Interrupt Switch 100V/200Amps

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

AN-ABCD-300, 300 Amp Artificial Network, EV HV Testing

AN-ABCD-300, 300 Amp Artificial Network, EV HV Testing

AN-ABCD-60, 60 Amp Artificial Network, EV HV Testing

AN-ABCD-60, 60 Amp Artificial Network, EV HV Testing

100-TS, VW 80000 / LV 124 : Battery test systems Test systems for 12 V | 24 V | 48 V batteries

100-TS, VW 80000 / LV 124 : Battery test systems Test systems for 12 V | 24 V | 48 V batteries

100-TS, VW 80300 / LV 123 / LV 148 : HV Electric vehicle test systems

100-TS, VW 80300 / LV 123 / LV 148 : HV Electric vehicle test systems

60-1C, 0-60V, 9-2000+kW, DC Power Supply, Sink/Source

60-1C, 0-60V, 9-2000+kW, DC Power Supply, Sink/Source

80-1C, 0-80V, 9-2000+kW, DC Power Supply, Sink/Source

80-1C, 0-80V, 9-2000+kW, DC Power Supply, Sink/Source

160-1C, 0-160V, 18-2000+kW, DC Power Supply, Sink/Source

160-1C, 0-160V, 18-2000+kW, DC Power Supply, Sink/Source

Products

FIS 100-200 Fast Interrupt Switch 100V/200Amps

  • High current power stage (uni-directional)
  • Up to 32 channels for switching low-current signals (bi-directional)
  • Switching of resistive, inductive, capacitive passive, and active loads/devices
  • Input voltage up to 100V
  • Output current up to 200A DC

400 - 6112, 2-Ch, 250kS/s, AnyWave Control Unit

WaveMaster + AnyWave

BOLAB WaveMaster software and the BOLAB AnyWave control unit allow the control of power supplies as well as 4 quadrant amplifiers via the analog interfaces.

The powerful and easy-to-use BOLAB WaveMaster software is unique in the world. Without any knowledge in software development, designing ordinary and complex waveforms is very easy. A graphic waveform editor allows the generation

of individual curves in no time. Also, with tabular input, all types of waveforms can be produced instantly.

400 - 6361, 2-Ch, 2.8MS/s, AnyWave Control Unit

WaveMaster + AnyWave

BOLAB WaveMaster software and the BOLAB AnyWave control unit allow the control of power supplies as well as 4 quadrant amplifiers via the analog interfaces.

The powerful and easy-to-use BOLAB WaveMaster software is unique in the world. Without any knowledge in software development, designing ordinary and complex waveforms is very easy. A graphic waveform editor allows the generation

of individual curves in no time. Also, with tabular input, all types of waveforms can be produced instantly.

100-TS, 4-Quadrant Voltage Amplifiers 400 W - 54,000 W

  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

100-TS, 4-Quadrant Current Amplifiers 400 W - 54,000 W

  • DC - 200 kHz bandwidth DC 
  • MHz (small signal -3 dB)
  • Output voltage ±75 Vpk
  • Rise / fall time 100 V/µs
  • USB interface standard, LAN optional
  • Analog control input 0 ... ±10 V for control of voltage and current
  • Monitor outputs for measured voltage and current values (not all models)
  • Modularly extensible via master-slave mode
  • Parallel and Series Connections for two or more units

AN-ABCD-300, 300 Amp Artificial Network, EV HV Testing

AN-Series is an artificial Network that electrically recreates the vehicular power-net impedance for component tests of voltage class B (high voltage) components in laboratories and test benches. The AN-Series uses an analog system with a bandwidth covering up to 150 kHz. An artificial network like the AN-Series is crucial for the proper testing of all voltage class B components in both hybrid and electric vehicles.

In accordance with LV123, ISO 21498, MBN 11123, VW 80300, and IEC 61851-23.

AN-ABCD-60, 60 Amp Artificial Network, EV HV Testing

AN-Series is an artificial Network that electrically recreates the vehicular power-net impedance for component tests of voltage class B (high voltage) components in laboratories and test benches. The AN-Series uses an analog system with a bandwidth covering up to 150 kHz. An artificial network like the AN-Series is crucial for the proper testing of all voltage class B components in both hybrid and electric vehicles.

In accordance with LV123, ISO 21498, MBN 11123, VW 80300, and IEC 61851-23.

100-TS, VW 80000 / LV 124 : Battery test systems Test systems for 12 V | 24 V | 48 V batteries

  • Protocol reports
  • Generation of waveforms with synchronous data acquisition 
  • Modular Expandable
  • Individual Waveform Generation
  • Standard Libraries included
  • Unlimited Waveform size
  • 2 different Waveforms synchronously 
  • DLL's for LabView, Vector CANoe / CAPL, C#, C++, ANSI C, Python, etc.
  • Simulation of imported oscilloscope waveform

100-TS, VW 80300 / LV 123 / LV 148 : HV Electric vehicle test systems

BOLAB´s new and world´s unique solutions in testing High Voltage profiles for Electric Vehicles are very powerful, flexible, and modular.

Three different solutions for high-speed testing, a medium-range for covering most profiles, and a low budget. Powerful solutions for starting and gaining experience are available.

Modularity is one of the most important characteristics of BOLAB´s systems.

Start with a “small” system of 1 KW (1.000 V, 15 A) and expand module by module as applications require and budgets allow.

It was never this easy to get involved with high voltage tests for Electric Vehicles and to build up these tests to a most powerful solution.

60-1C, 0-60V, 9-2000+kW, DC Power Supply, Sink/Source

    • Technologically advanced, fast-switching, compact 19-inch power supplies
    • High control dynamics in the 100...200 µs range – even at higher power levels
    • Exceptional current accuracy of <0.02% FS, additional high-resolution current measurement range included as standard
    • Full power regeneration and a high degree of efficiency, resulting in a significant reduction of energy consumption and heat dissipation, low acoustic noise
    • Wide current-voltage range with an auto-ranging factor of 3
    • Full digital CV, CC, CP, CR, and Ri-Sim control modes

 

80-1C, 0-80V, 9-2000+kW, DC Power Supply, Sink/Source

    • Technologically advanced, fast-switching, compact 19-inch power supplies
    • High control dynamics in the 100...200 µs range – even at higher power levels
    • Exceptional current accuracy of <0.02% FS, additional high-resolution current measurement range included as standard
    • Full power regeneration and a high degree of efficiency, resulting in a significant reduction of energy consumption and heat dissipation, low acoustic noise
    • Wide current-voltage range with an auto-ranging factor of 3
    • Full digital CV, CC, CP, CR, and Ri-Sim control modes

 

160-1C, 0-160V, 18-2000+kW, DC Power Supply, Sink/Source

    • Technologically advanced, fast-switching, compact 19-inch power supplies
    • High control dynamics in the 100...200 µs range – even at higher power levels
    • Exceptional current accuracy of <0.02% FS, additional high-resolution current measurement range included as standard
    • Full power regeneration and a high degree of efficiency, resulting in a significant reduction of energy consumption and heat dissipation, low acoustic noise
    • Wide current-voltage range with an auto-ranging factor of 3
    • Full digital CV, CC, CP, CR, and Ri-Sim control modes

 


Loading...