60-1C, 0-60V, 9-2000+kW, DC Power Supply, Sink/Source

60-1C, 0-60V, 9-2000+kW, DC Power Supply, Sink/Source

80-1C, 0-80V, 9-2000+kW, DC Power Supply, Sink/Source

80-1C, 0-80V, 9-2000+kW, DC Power Supply, Sink/Source

160-1C, 0-160V, 18-2000+kW, DC Power Supply, Sink/Source

160-1C, 0-160V, 18-2000+kW, DC Power Supply, Sink/Source

320-1C, 0-320V, 36-2000+kW, DC Power Supply, Sink/Source

320-1C, 0-320V, 36-2000+kW, DC Power Supply, Sink/Source

Floor Ground Plane  & Vertical Wall

Floor Ground Plane & Vertical Wall

ESD Test Table Kit

ESD Test Table Kit

CDN 5416 / 7416 / 10416 / 12416, 3-Phase, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5416 / 7416 / 10416 / 12416, 3-Phase, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 10216 & 12216, 2-line, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 10216 & 12216, 2-line, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5432 / 7432 / 10432 / 12432, 3-Phase, 32 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5432 / 7432 / 10432 / 12432, 3-Phase, 32 Amp, Surge and EFT/burst, Coupling Decoupling Network

SESD 302x Test tip's for ESD

SESD 302x Test tip's for ESD

SESD 271 Vertical Coupling Plate (VCP) for ESD

SESD 271 Vertical Coupling Plate (VCP) for ESD

SESD 272 Grounding cable for ESD

SESD 272 Grounding cable for ESD

Products

60-1C, 0-60V, 9-2000+kW, DC Power Supply, Sink/Source

    • Technologically advanced, fast-switching, compact 19-inch power supplies
    • High control dynamics in the 100...200 µs range – even at higher power levels
    • Exceptional current accuracy of <0.02% FS, additional high-resolution current measurement range included as standard
    • Full power regeneration and a high degree of efficiency, resulting in a significant reduction of energy consumption and heat dissipation, low acoustic noise
    • Wide current-voltage range with an auto-ranging factor of 3
    • Full digital CV, CC, CP, CR, and Ri-Sim control modes

 

80-1C, 0-80V, 9-2000+kW, DC Power Supply, Sink/Source

    • Technologically advanced, fast-switching, compact 19-inch power supplies
    • High control dynamics in the 100...200 µs range – even at higher power levels
    • Exceptional current accuracy of <0.02% FS, additional high-resolution current measurement range included as standard
    • Full power regeneration and a high degree of efficiency, resulting in a significant reduction of energy consumption and heat dissipation, low acoustic noise
    • Wide current-voltage range with an auto-ranging factor of 3
    • Full digital CV, CC, CP, CR, and Ri-Sim control modes

 

160-1C, 0-160V, 18-2000+kW, DC Power Supply, Sink/Source

    • Technologically advanced, fast-switching, compact 19-inch power supplies
    • High control dynamics in the 100...200 µs range – even at higher power levels
    • Exceptional current accuracy of <0.02% FS, additional high-resolution current measurement range included as standard
    • Full power regeneration and a high degree of efficiency, resulting in a significant reduction of energy consumption and heat dissipation, low acoustic noise
    • Wide current-voltage range with an auto-ranging factor of 3
    • Full digital CV, CC, CP, CR, and Ri-Sim control modes

 

320-1C, 0-320V, 36-2000+kW, DC Power Supply, Sink/Source

    • Technologically advanced, fast-switching, compact 19-inch power supplies
    • High control dynamics in the 100...200 µs range – even at higher power levels
    • Exceptional current accuracy of <0.02% FS, additional high-resolution current measurement range included as standard
    • Full power regeneration and a high degree of efficiency, resulting in a significant reduction of energy consumption and heat dissipation, low acoustic noise
    • Wide current-voltage range with an auto-ranging factor of 3
    • Full digital CV, CC, CP, CR, and Ri-Sim control modes

 

Floor Ground Plane & Vertical Wall

  • Low-profile 12'×10' floor plane with matching vertical wall (up to 12'×10') in galvanized steel.
  • Staggered two-layer floor design: wide metal-to-metal overlap, ultra-low impedance, almost zero step height.
  • Fast install (1–2 days) with full bonding/continuity verification to the building ground or a shielded room.
  • Engineered to meet IEC 61000, CISPR, and MIL-STD-461 ground-plane requirements.
  • Custom sizes/materials (steel, aluminum, copper), edge ramps, LISN pads, and cable trenches available.
  • Delivers repeatable EMC/ESD results by minimizing loop impedance and stray coupling paths.

 

ESD Test Table Kit

The ESD Test Table Kit is a simple inexpensive solution for your ESD testing. Complies to the requirements of IEC 61000-4-2 and can be used for additional standards. Comes with a Horizontal Coupling Plane (HCP), resistive cable to tie HCP to floor ground plane, bleeder wire for discharging ungrounded battery powered EUTs, 0.05mm insulator and an alternative low impedance ground for using the table for additional setups such as IEC 61000-4-6 requirements.

CDN 5416 / 7416 / 10416 / 12416, 3-Phase, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

The capacitive Coupling-/Decoupling Networks CDN 5416/7416/10416/12416 are used in combination with the Multi-CE5 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

CDN 10216 & 12216, 2-line, 16 Amp, Surge and EFT/burst, Coupling Decoupling Network

The capacitive Coupling-/Decoupling Network CDN 10216 & 12216 is used in combination with the Surge generators PG 7-250, PG 10-504 or PG 12-804 and allows superimposition of surge test pulses to the single-phase power supply voltage of the device under test. The test set-up is suitable for immunity testing of electronic systems and devices according to IEC 61000-4-4, IEC 61000-4-5 and IEEE 587.

CDN 5432 / 7432 / 10432 / 12432, 3-Phase, 32 Amp, Surge and EFT/burst, Coupling Decoupling Network

The capacitive Coupling-/Decoupling Networks CDN 5432/7432/10432/12432 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

SESD 302x Test tip's for ESD

Avalible ESD Test Tips for replacment or different aplications.

SESD 271 Vertical Coupling Plate (VCP) for ESD

The Vertical Coupling Plate (VCP) is used in conjunction with ESD generators to simulate indirect discharges on metallic objects that are near a test object. The bleeder resistors contained in the ground wire of the VCP serve to prevent the applied charge from vanishing immediately after the discharge of the ESD generator to the VCP, thereby increasing the effect of the ESD test.

SESD 272 Grounding cable for ESD

2m Grounding cable for ESD immunity tests

Loading...