CATAGORY

CWG-CE5: 5kV Surge,  1.2/50µs Voltage, 8/20µs Current

CWG-CE5: 5kV Surge, 1.2/50µs Voltage, 8/20µs Current

CWG-CE7  7kV SURGE, 1.2/50µs VOLTAGE, 8/20µs CURRENT

CWG-CE7 7kV SURGE, 1.2/50µs VOLTAGE, 8/20µs CURRENT

BCK 400 F  Calibration kit for EFT/burst Generators

BCK 400 F Calibration kit for EFT/burst Generators

IMP 8, Impedance matching network for IEC 61000-4-5

IMP 8, Impedance matching network for IEC 61000-4-5

SCK 105, Surge Calibration Kit

SCK 105, Surge Calibration Kit

SCK 105 inBox, Surge Calibration Kit

SCK 105 inBox, Surge Calibration Kit

VPS 250, Automatic Variack 0-250V 16Amps

VPS 250, Automatic Variack 0-250V 16Amps

Foot-switch Trigger

Foot-switch Trigger

EFT 2012 EFT/Burst Capacitive Coupling Clamp

EFT 2012 EFT/Burst Capacitive Coupling Clamp

CAR CDN 2012 EFT/Burst Capacitive Coupling Clamp ISO

CAR CDN 2012 EFT/Burst Capacitive Coupling Clamp ISO

CDN 5463 / 7463 / 10463 / 12463, 3-Phase, 63 Amp, Surge and EFT/burst, Coupling Decoupling Network

CDN 5463 / 7463 / 10463 / 12463, 3-Phase, 63 Amp, Surge and EFT/burst, Coupling Decoupling Network

DCS06 Test Generator for DEF-STN 59-411

DCS06 Test Generator for DEF-STN 59-411

Products

CWG-CE5: 5kV Surge, 1.2/50µs Voltage, 8/20µs Current

The CWG-CE5 is a compact EMC test unit designed for testing electromagnetic immunity against pulsed and conducted interference. Demonstrating such immunity is generally a requirement for compliance with the European EMC directive, a necessary step leading to the CE mark.

CWG-CE7 7kV SURGE, 1.2/50µs VOLTAGE, 8/20µs CURRENT

The Combination Wave Generator CWG-CE7 is a combined impulse-current-/impulse-voltage generator which, for high-impedance loads, RL > 100?, delivers a standard impulse voltage with waveform 1.2/50?s and, for short-circuited output, a standard impulse current with waveform 8/20?s.

BCK 400 F Calibration kit for EFT/burst Generators

The Burst Calibration Kit has been designed to measure the pulse output voltage and the pulse output current of burst generators, e.g. the EFTG-CE5 or the burst generator sub-unit of the Multi-CE5. It essentially consists of a load resistor, a pulse voltage divider, and a double-shielded coaxial cable. ? Burst Calibration Kit ? Input voltage: 5 kV ? Ratio, 200/400:1 ? Bandwidth: 400 MHz

IMP 8, Impedance matching network for IEC 61000-4-5

The external impedance IMP8 is the impedance, required for the pulse specifications according to standard IEC 61000-4-5 Ed.3, for measuring the pulse output voltage of surge generators.

SCK 105, Surge Calibration Kit

The Surge Calibration Kit has been designed to measure the pulse output voltage and the pulse output current of surge generators, e.g. a combination wave generator. It essentially consists of a pulse voltage divider, a pulse current measuring resistor, and a double-shielded coaxial cable.

SCK 105 inBox, Surge Calibration Kit

The Surge Calibration Kit has been designed to measure the pulse output voltage and the pulse output current of surge generators, e.g. a combination wave generator. It essentially consists of a pulse voltage divider, a pulse current measuring resistor, and a double-shielded coaxial cable. The unit is easy to connect and use for everyday pulse verification.

VPS 250, Automatic Variack 0-250V 16Amps

Motor-driven variable transformer, controlled by Multi-CE5 or Multi-CE7, used for power supply variation acc. to IEC 61000-4-11 and setting current for IEC 61000-4-8 Magnetic fields

Foot-switch Trigger

Footswitch to trigger certain generator functions.

EFT 2012 EFT/Burst Capacitive Coupling Clamp

The Capacitive Coupling Clamp, EFTC 2012, provides the ability to couple Burst / EFT pulses to data lines. It can also be used for coupling to main lines where no CDN is available, for example, high current lines >200 A.

CAR CDN 2012 EFT/Burst Capacitive Coupling Clamp ISO

The coupling clamp CDN 2012 conforms exactly to the requirements of ISO 7637-3 and other standards, guaranteeing that tests are carried out in strict compliance with the standard. The CDN allows the fast nanosecond pulse bursts ( ISO 3a and 3b) to be injected in cable runs. Very high impedance signal lines are also to be found in vehicles on which the disruptive effects of ISO pulses 1 and 2 can also show up through capacitive coupling.

CDN 5463 / 7463 / 10463 / 12463, 3-Phase, 63 Amp, Surge and EFT/burst, Coupling Decoupling Network

The capacitive Coupling-/Decoupling Networks CDN 5463/7463/10463/12463 are used in combination with the Multi-CE5 / Multi-CE7 or the Surge generators PG 7-250, PG 10-504, PG 12-804 and allow superimposition of surge and burst test pulses to the 3-phase mains voltage of the device under test.

DCS06 Test Generator for DEF-STN 59-411

The Conformity Assessment Business Model DCS06 Test Generator has been designed to operate with its complementary injection clamp to fully meet the pulse requirements of DCS06 when tested into a 5? load. It operates from an intuitive touch screen interface and has full phase synchronization up to 800 Hz input frequency with 1-degree steps. It has been designed with future revisions of the test standard in mind.

Loading...