SW 9606, 9 kHz - 200 MHz  Current Clamp

SW 9606, 9 kHz - 200 MHz Current Clamp

SW 9605, 9 kHz - 80 MHz  Current Clamp

SW 9605, 9 kHz - 80 MHz Current Clamp

SW 9603, 9 kHz - 150 MHz  Current Transformer

SW 9603, 9 kHz - 150 MHz Current Transformer

SW 9602, 10 kHz - 200 MHz  Current Transformer

SW 9602, 10 kHz - 200 MHz Current Transformer

CDN ABCL-35 Decoupling Clamp

CDN ABCL-35 Decoupling Clamp

CDN EMCL-20 / CDN EMCL-35 EM Clamp

CDN EMCL-20 / CDN EMCL-35 EM Clamp

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDG CMP-46 Current Monitoring Probe, with Calibration Set

CDG CMP-46 Current Monitoring Probe, with Calibration Set

Products

SW 9606, 9 kHz - 200 MHz Current Clamp

  • Clamp-on Current Clamp
  • 0.09 - 200 MHz
  • Transfer Impedance: 8 Ohm for wires up to 23 mm

SW 9605, 9 kHz - 80 MHz Current Clamp

  • Clamp-on Current Clamp
  • 0.09 - 80 MHz
  • Transfer Impedance: 1 Ohm for wires up to 23 mm

SW 9603, 9 kHz - 150 MHz Current Transformer

  • Current Transformer
  • Shielded
  • 0.09 - 150 MHz
  • Transfer Impedance: 1 Ohm for wires up to 14 mm

SW 9602, 10 kHz - 200 MHz Current Transformer

  • Current Transformer
  • Shielded
  • 0.01 - 200 MHz
  • Transfer Impedance: 1 Ohm for wires up to 6.5 mm

CDN ABCL-35 Decoupling Clamp

CDN ABCL-35 Decoupling Clamp for immunity according to IEC / EN 61000-4-6 Ed. 4.0 100 kHz – 1000 MHz Features: For additional decoupling at immunity testing according to IEC / EN 61000-4-6 Suitable for cables up to 20mm diameter

CDN EMCL-20 / CDN EMCL-35 EM Clamp

EM Clamp for immunity tests IEC / EN 61000-4-6 Ed. 4.0 • EM Clamp for immunity testing of cables with up to 20 (35) mm diameter • High coupling factor: less than 15 watts amplifier output power is required to obtain a test level of 10 V • Calibration unit and calibration data are supplied with each unit.

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

CDG CMP-45 Current monitoring probe • Cable diameters up to 45 mm • Frequency range 10 kHz to 400 MHz • Foldable, easy positioning on the conductor / cable • For BCI testing acc. to ISO 11452-4 and others • Insertion impedance < 2,5 ?

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005, MIL-STD-461, DO-160 and IEC 61000-4-6 - Frequency range from 4 kHz up to 400 MHz - Designed for BCI testing 

CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

BCI-P1 Bulk Current Injection Probe 10 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005 and IEC 61000-4-6 - Frequency range from 1 MHz up to 400 MHz - Designed for automotive BCI testing - Low insertion loss (1MHz - 400MHz) to test bellow 1MHz (IEC/DO/MIL) see CDN BCI-P1_MT-1

CDG CMP-46 Current Monitoring Probe, with Calibration Set

CDG CMP-46 Current monitoring probe • Cable diameters up to 45 mm • Frequency range 10 kHz to 400 MHz • For BCI testing acc. to ISO 11452-4 and others • Insertion impedance < 2,5 ?