VTSD 9561 F, 10dB, Diode Pulse Limiter

VTSD 9561 F, 10dB, Diode Pulse Limiter

NNLK 8121, 9 kHz - 30 MHz, 400V / 100A, 50 µH, 4 Path LISN

NNLK 8121, 9 kHz - 30 MHz, 400V / 100A, 50 µH, 4 Path LISN

NNLK 8122, 9 kHz - 30 MHz, 1000VDC / 50A, 50 µH, 2 Path LISN

NNLK 8122, 9 kHz - 30 MHz, 1000VDC / 50A, 50 µH, 2 Path LISN

NNLK 8129, 150 kHz - 30 MHz, 400V / 200A, 50 µH, 4 Path LISN

NNLK 8129, 150 kHz - 30 MHz, 400V / 200A, 50 µH, 4 Path LISN

NNLK 8129-2 HV, 150 kHz - 30 MHz, 1000V / 200A, 50 µH, 2 Path LISN

NNLK 8129-2 HV, 150 kHz - 30 MHz, 1000V / 200A, 50 µH, 2 Path LISN

NNLK 8130, 150 kHz - 30 MHz, 400VAC/400A, 50 µH, 4 Path LISN

NNLK 8130, 150 kHz - 30 MHz, 400VAC/400A, 50 µH, 4 Path LISN

NNLK 8140, 150 kHz - 30 MHz, 1000V/800A, 50 µH, Single Path LISN

NNLK 8140, 150 kHz - 30 MHz, 1000V/800A, 50 µH, Single Path LISN

TBL5016-1 50uH 16A Line Impedance Stabilization Network LISN

TBL5016-1 50uH 16A Line Impedance Stabilization Network LISN

TBL5016-3 50uH 16A Line Impedance Stabilization Network LISN

TBL5016-3 50uH 16A Line Impedance Stabilization Network LISN

TBL5032-3 50uH 32A Line Impedance Stabilization Network LISN

TBL5032-3 50uH 32A Line Impedance Stabilization Network LISN

TBL50100-1 50uH Line Impedance Stabilization Network LISN

TBL50100-1 50uH Line Impedance Stabilization Network LISN

Products

VTSD 9561 F, 10dB, Diode Pulse Limiter

Diode Pulse Limiter with built-in 10 dB high power attenuator and fuse lamp to protect sensitive measuring equipment when measuring spectra with high energy. Thanks to the built-in fuse lamp, serious overload situations of sensitive equipment can be recognized fast and reliably. A replacement bulb is placed inside the unit. The pulse limiter prevents expensive equipment defects. The very flat frequency response allows high measurement accuracy, even if only a few sample values are used for correction.

NNLK 8121, 9 kHz - 30 MHz, 400V / 100A, 50 µH, 4 Path LISN

  • High Current 4 path LISN (3-Phase)
  • Line Impedance Stabilisation Network
  • 9 kHz to 30 MHz
  • 400 VAC, 630 VDC, 100 A
  • (50 µH+5 Ω) || 50 Ω   
  • CISPR 16-1-2

NNLK 8122, 9 kHz - 30 MHz, 1000VDC / 50A, 50 µH, 2 Path LISN

  • High Current 2 path LISN (3-Phase)
  • Line Impedance Stabilisation Network
  • 9 kHz to 30 MHz
    • With 250uH multilayer choke adding better decoupling 9 kHz is possible
  • 750 VAC, 1000 VDC, 50 A 
  • (50 µH + 5 Ω)  || 50 Ω 
  • CISPR 16-1-2

NNLK 8129, 150 kHz - 30 MHz, 400V / 200A, 50 µH, 4 Path LISN

  • High Current 4 path LISN (3-Phase)
  • Line Impedance Stabilisation Network
  • 150 kHz to 30 MHz
  • 400 VAC, 800 VDC, 200 A (
  • 50 µH || 50 Ω 
  • CISPR 16-1-2

NNLK 8129-2 HV, 150 kHz - 30 MHz, 1000V / 200A, 50 µH, 2 Path LISN

  • High Current 2 path LISN (Dingle-Phase or DC)
  • Line Impedance Stabilisation Network
  • 150 kHz to 30 MHz
  • 1000 VAC, 1000 VDC, 200 A 
  • 50 µH || 50 Ω 
  • CISPR 16-1-2

NNLK 8130, 150 kHz - 30 MHz, 400VAC/400A, 50 µH, 4 Path LISN

  • High Current 4 path LISN (3-Phase)
  • Line Impedance Stabilisation Network
  • 150 kHz to 30 MHz
  • 400/700VAC, 630 VDC, 400 A 
  • 50 µH || 50 Ω (+/- 20 %) 
  • CISPR 16-1-2

NNLK 8140, 150 kHz - 30 MHz, 1000V/800A, 50 µH, Single Path LISN

  • High Current High Voltage LISN
  • Line Impedance Stabilisation Network
  • 150 kHz to 30 MHz
  • 1000V AC/DC,  800 A
  • 50 µH || 50 Ω (+/- 20 %) 
  • CISPR 16-1-2

TBL5016-1 50uH 16A Line Impedance Stabilization Network LISN

The TBL5016-1 50µH LISN is a device required to setup conducted noise measurements of DC or AC-powered electronic equipment. It is designed according to CISPR 16-1-2 and MIL-STD-461F standard and characterized in the frequency range of 9kHz to 100 MHz.

TBL5016-3 50uH 16A Line Impedance Stabilization Network LISN

The TBL5016-3 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9 kHz to 30MHz, according to the CISPR 16-1-2 standard. The device is designed for testing 3-phase and single-phase, AC-powered equipment with supply voltages up to a maximum 450V/260V and 16A.

TBL5032-3 50uH 32A Line Impedance Stabilization Network LISN

The TBL5032-3 is a Line Impedance Stabilization Network for the measurement of line-conducted interference within the range of 9 kHz to 30MHz, according to the CISPR 16-1-2 standard. The device is designed for testing 3-phase and single phase, AC-powered equipment with supply voltages up to maximum 450V/260V and 32A. 

TBL50100-1 50uH Line Impedance Stabilization Network LISN

The TBL50100-1 50µH is a single channel 50 ohm // 50 µH LISN for the frequency range 150 kHz – 30 MHz according to CISPR 16-1-2.  In addition to conducted noise measurements on AC or DC supplied equipment, the LISN can be used to establish a defined impedance for a variety of other standardized tests.