Categories

EMProbe-DBM-E6 — 6-Axis Robotic Near-Field EMI Diagnostics on the Bench

EMProbe-DBM-E6 — 6-Axis Robotic Near-Field EMI Diagnostics on the Bench

eNFPKIT, Educational Kit EM Near Field Probe Kit w/Camera & Software

eNFPKIT, Educational Kit EM Near Field Probe Kit w/Camera & Software

CAR TE 21 Transient Emission Test  to ISO 7637-2

CAR TE 21 Transient Emission Test to ISO 7637-2

MGA 1033; Magnetic Immunity DC-250 kHz, 800 Watts

MGA 1033; Magnetic Immunity DC-250 kHz, 800 Watts

MF EASY, DC-400 kHz, MAGNETIC FIELD EXPOSURE ASSESSMENT SYSTEM

MF EASY, DC-400 kHz, MAGNETIC FIELD EXPOSURE ASSESSMENT SYSTEM

HFa-1-16-Ref, 16 Amp single phase Harmonics and Flicker w/ Impedance Reference

HFa-1-16-Ref, 16 Amp single phase Harmonics and Flicker w/ Impedance Reference

HFa-1S, 16 Amp single phase Harmonics and Flicker

HFa-1S, 16 Amp single phase Harmonics and Flicker

HFa-3-16-Ref, 16 Amp 3-phase Harmonics and Flicker w/Reference Impedance

HFa-3-16-Ref, 16 Amp 3-phase Harmonics and Flicker w/Reference Impedance

HFa-3-16, 16 Amp 3-phase Harmonics and Flicker

HFa-3-16, 16 Amp 3-phase Harmonics and Flicker

HFa-3-35-Ref, 35 Amp 3-phase Harmonics and Flicker w/Reference Impedance

HFa-3-35-Ref, 35 Amp 3-phase Harmonics and Flicker w/Reference Impedance

LSAOL 1.2 Laser-Powered Analog Optical Link

LSAOL 1.2 Laser-Powered Analog Optical Link

HFa-3-75-500-Ref, 75 Amp 3-phase Harmonics and Flicker w/Reference Impedance

HFa-3-75-500-Ref, 75 Amp 3-phase Harmonics and Flicker w/Reference Impedance

Products

EMProbe-DBM-E6 — 6-Axis Robotic Near-Field EMI Diagnostics on the Bench

  • See EMI instantly with real-time 150 kHz–6 GHz emissions mapping
  • Pinpoint noise sources fast using a dense 1,218-probe near-field array
  • No external instruments required — integrated spectrum analyzer built in
  • Validate fixes in seconds, not hours or days
  • Cut compliance risk and testing time with bench-top pre-compliance diagnostics

eNFPKIT, Educational Kit EM Near Field Probe Kit w/Camera & Software

" An RF Probe Kit on Steroids"

  • Fully integrated with Y.I.C. Technologies EMViewer software and EMProbe
  • Normalization and correction when using the EMViewer software
  • Flat response within the range of operation
  • Slim Design and Protective Coating
  • 18GHz Measured Cable included
  • Lectures & Explanation Document
  • Designed By Prof. Arturo Mediano, University of Zaragoza, Spain

CAR TE 21 Transient Emission Test to ISO 7637-2

  • Modular construction
  • Electronically and mechanically (+ life time counter) triggerable load switches
  • Artificial Network with temperature control
  • Shunt resistors: 10 / 20 / 40 / 120Ω
  • Battery current: 50A / 100A

MGA 1033; Magnetic Immunity DC-250 kHz, 800 Watts

The compact magnetic field generator and analyzer MGA 1033 allows susceptibility tests against magnetic fields from DC to 250 kHz according to the standard EN 55103-2 and their measurement according to EN 55103-1. In addition, EMC tests are possible according to various standards such as automotive, avionic and MIL-STD.; Generation of magnetic fields from DC to 250 kHz; Field strength up to 1000 A/m; EN 55103-1/2, MIL-STD 461, Automotive etc.; Accessories: Loop sensors, Helmholtz coils etc.;

MF EASY, DC-400 kHz, MAGNETIC FIELD EXPOSURE ASSESSMENT SYSTEM

The MF EASY is a scalable and flexible multichannel measurement and assessment system for magnetic fields in the frequency range DC – 400 kHz. It is available with 5 or 10 (on request up to 15) fully isotropic measurement channels enabling simultaneous magnetic field measurements on 5 or 10 (15) measurement positions.

Different standard probe types (sizes and shapes) are available for the MF EASY. Customized probes are available on request. Iso-centrically arranged coil and Hall sensor enable a measurement frequency range from DC to 400 kHz and a measurement sensitivity suitable for assessing human exposure.

HFa-1-16-Ref, 16 Amp single phase Harmonics and Flicker w/ Impedance Reference

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 Harmoinc Emissions
  • IEC 61000-3-3 Flicker Emissons
  • USB controlled, Windows 10 compatible software included
  • 16 Amp, 120, and 230 Voltages, 50/60Hz

HFa-1S, 16 Amp single phase Harmonics and Flicker

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 Harmoinc Emissions
  • IEC 61000-3-3 Flicker Emissons
  • USB controlled, Windows 10 compatible software included
  • 16 Amp, 120, and 230 Voltages, 50/60Hz

HFa-3-16-Ref, 16 Amp 3-phase Harmonics and Flicker w/Reference Impedance

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 Harmoinc Emissions
  • IEC 61000-3-3 Flicker Emissions
  • USB controlled, Windows 10 compatible software included
  • Singel and 3 phase 16 Amp, 120 and 230 Voltages, 50/60Hz
  • Includes Refernec impedance

HFa-3-16, 16 Amp 3-phase Harmonics and Flicker

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 Harmoinc Emissions
  • IEC 61000-3-3 Flicker Emissions
  • USB controlled, Windows 10 compatible software included
  • Singel and 3 phase 16 Amp, 120 and 230 Voltages, 50/60Hz

HFa-3-35-Ref, 35 Amp 3-phase Harmonics and Flicker w/Reference Impedance

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 &  IEC 61000-3-12 Harmoinc Emissions
  • IEC 61000-3-3 &  IEC 61000-3-11 Flicker Emissions
  • USB controlled, Windows 10 compatible software included
  • Singel and 3 phase 35 Amp, 120 and 230 Voltages, 50/60Hz
  • Includes Reference Impedance

LSAOL 1.2 Laser-Powered Analog Optical Link

LSAOL 1.2 Laser-Powered Analog Optical Link

  • Laser-powered RF over fiber — no batteries required
  • Wideband coverage from 1 MHz to 3 / 4 / 6 GHz
  • Eliminates coaxial cable loss and grounding issues
  • Modular RX/TX configuration with optional LNA
  • >100 m fiber length for EMC chambers and antenna measurements
  • Ethernet control with SCPI for automated test systems

 

HFa-3-75-500-Ref, 75 Amp 3-phase Harmonics and Flicker w/Reference Impedance

  • Full compliant system meeting the requirements 
  • IEC 61000-3-2 &  IEC 61000-3-12 Harmoinc Emissions
  • IEC 61000-3-3 &  IEC 61000-3-11 Flicker Emissions
  • USB controlled, Windows 10 compatible software included
  • Singel and 3 phase 16 Amp, 120 and 230 Voltages, 50/60Hz
  • Includes Refernec impedance


Loading...