Call For More Details: +1 (703) 774-7505
Phone : +1 (703) 774-7505

This part of IEC 61000 specifies immunity requirements for electrical and electronic equipment (equipment, devices) when exposed to radiated electromagnetic energy from RF transmitters used in the immediate vicinity. It specifies test severity levels (test levels) and the required test procedures. The applicable frequency range is 9 kHz to 6 GHz. Equipment (equipment) in fixed equipment (installations) exposed to the (mobile) fields of mobile transmitters, mobile equipment (equipment) exposed to the (fixed) fields of fixed transmitters, and mobile equipment (equipment Devices) exposed to the fields of other mobile transmitters.
30kHz - 1MHz
Use with FESP 5132
Per IEC 61000-4-39