SESD 302x Test tip's for ESD

SESD 302x Test tip's for ESD

SESD 271 Vertical Coupling Plate (VCP) for ESD

SESD 271 Vertical Coupling Plate (VCP) for ESD

SESD 272 Grounding cable for ESD

SESD 272 Grounding cable for ESD

SESD 8800-4: ESD Verification Set

SESD 8800-4: ESD Verification Set

CDN 504U / CDN 508U,  4/8-Line,  Surge and EFT/burst, Coupling Decoupling Network

CDN 504U / CDN 508U, 4/8-Line, Surge and EFT/burst, Coupling Decoupling Network

PG 12-804  12kV Surge CWG

PG 12-804 12kV Surge CWG

PG 10-504: 10kV Surge CWG

PG 10-504: 10kV Surge CWG

PG 6-364: HV Pulse Generator

PG 6-364: HV Pulse Generator

CWG-CE5: 5kV Surge,  1.2/50µs Voltage, 8/20µs Current

CWG-CE5: 5kV Surge, 1.2/50µs Voltage, 8/20µs Current

EFTG-CE5: 5kV, EFT 5/50ns, 1-1000 kHz

EFTG-CE5: 5kV, EFT 5/50ns, 1-1000 kHz

RW-CE7: 7kV Ringwave, 5µs 100 kHz

RW-CE7: 7kV Ringwave, 5µs 100 kHz

PFS-CE-16: Dips/Drops/Variations

PFS-CE-16: Dips/Drops/Variations

Products

SESD 302x Test tip's for ESD

Avalible ESD Test Tips for replacment or different aplications.

SESD 271 Vertical Coupling Plate (VCP) for ESD

The Vertical Coupling Plate (VCP) is used in conjunction with ESD generators to simulate indirect discharges on metallic objects that are near a test object. The bleeder resistors contained in the ground wire of the VCP serve to prevent the applied charge from vanishing immediately after the discharge of the ESD generator to the VCP, thereby increasing the effect of the ESD test.

SESD 272 Grounding cable for ESD

2m Grounding cable for ESD immunity tests

SESD 8800-4: ESD Verification Set

ESD - Generators verified according to the standard International Electro technical Commission 61000-4-2, ISO 10605 and other. The measurements of the single pulses take place with a special 2 ohm shunt. For the correct verification of the ESD impulses an oscilloscope is necessary with a minimum bandwidth of - 2 GHz acc. IEC 61000-4-2, 2008 and - 1 GHz acc. ISO 10605, 2008. The ESD verification set SESD 8800-4 works up to 4 GHz and fulfilled the request of the double bandwidth regarding to the measurement bandwidth.

CDN 504U / CDN 508U, 4/8-Line, Surge and EFT/burst, Coupling Decoupling Network

Designed for applying the impulse output voltage of the Combination wave/ Ring wave generator to interconnection lines of the equipment under test, acc. to IEC 61000-4-5, Fig9/ IEC 61000-4-12, Fig. 8. 

The coupling/decoupling network CDN 504/ 508 U essentially consists of a current compensated decoupling inductor, L1 – L4/L8, and a set of coupling impedances to be inserted in the coupling path. 

PG 12-804 12kV Surge CWG

The Combination Wave Generator PG 12-804 is a combined impulse-current-/impulse-voltage generator which, for high-impedance loads, RL > 100?, delivers a standard impulse voltage with waveform 1.2/50µs and, for short-circuited output, a standard impulse current with waveform 8/20µs. The generator allows surge testing of components and devices, galvanic coupling of surges to cable shields, shielded enclosures and cabinets as well as testing electromagnetic compatibility, EMC, of electronic devices and systems against pulsed and conducted interference.

PG 10-504: 10kV Surge CWG

The Combination Wave Generator PG 10-504 is a combined impulse-current-/impulse-voltage generator which, for high-impedance loads, RL > 100?, delivers a standard impulse voltage with waveform 1.2/50µs and, for short-circuited output, a standard impulse current with waveform 8/20µs. The generator allows surge testing of components and devices, the galvanic coupling of surges to cable shields, shielded enclosures and cabinets as well as testing electromagnetic compatibility, EMC, of electronic devices and systems against pulsed and conducted interference.

PG 6-364: HV Pulse Generator

The high-voltage impulse generator PG 6-364 generates standard impulse voltages with waveforms 1.2/50 µs and 10/700 µs. The Output voltage is adjustable between 0.2 kV and 6 kV. The polarity of the output voltage is selectable. Positive, negative or alternating polarity of the output voltage can be preselected. The generator is designed for dielectric testing of components and systems as well as testing of the electromagnetic compatibility of electronic systems and devices acc. to CCITT K17/K20/K22, ITU-T/K44, IEC 61000-4-5, VDE 0847.

CWG-CE5: 5kV Surge, 1.2/50µs Voltage, 8/20µs Current

The CWG-CE5 is a compact EMC test unit designed for testing electromagnetic immunity against pulsed and conducted interference. Demonstrating such immunity is generally a requirement for compliance with the European EMC directive, a necessary step leading to the CE mark.

EFTG-CE5: 5kV, EFT 5/50ns, 1-1000 kHz

The Electrical Fast Transient Generator EFTG-CE5 is a compact EMC test unit for testing electromagnetic immunity against electrical fast transients. The generator provides burst-pulses, which are adjustable in frequency, amplitude, duration and repetition rate. It is suitable to test the susceptibility levels of electrical systems and installations full compliant to IEC 61000-4-4.

RW-CE7: 7kV Ringwave, 5µs 100 kHz

High-voltage pulse generator producing Ring Wave 0.5 µs / 100 kHz acc. to IEEE 587. The output peak voltage can be preset continuously from 0.2 - 7 kV. Rise time 0.5µs to the first peak, ringing frequency 100 kHz. A built-in voltage divider allows the monitoring of the output voltage waveform. The generator comprises an electronically regulated high-voltage power supply, an energy storage capacitor, a high-voltage/high-current switch, a pulse forming network and control- and monitoring unit. Moreover, the generator includes a Coupling-/Decoupling Network (CDN) for single-phase power supply lines.

PFS-CE-16: Dips/Drops/Variations

The Power Fail Simulator PFS-CE-16 is a compact EMC test unit designed for testing electromagnetic immunity against interruption and variation of the power supply voltage acc. to IEC 61000-4-11. Demonstrating such immunity is generally a requirement of the European EMC directive, a necessary step leading to the final attachment of the CE mark.

Loading...