CABCI251R, 200W, 1.0 Ohm Shunt Resistor

CABCI251R, 200W, 1.0 Ohm Shunt Resistor

PG-C202 - Damped Sinusoid Generator CS116 +7dB levels

PG-C202 - Damped Sinusoid Generator CS116 +7dB levels

PG-C201 - Damped Sinusoid Generator 300A

PG-C201 - Damped Sinusoid Generator 300A

Customized PCI Generators

Customized PCI Generators

EMP300K-5-500, PCI Short pulse (E1) generator, 5kA

EMP300K-5-500, PCI Short pulse (E1) generator, 5kA

IPP3K-4MS, 260A, Intermediate Pulse (E2) Generator

IPP3K-4MS, 260A, Intermediate Pulse (E2) Generator

SESD 302x Test tip's for ESD

SESD 302x Test tip's for ESD

SESD 271 Vertical Coupling Plate (VCP) for ESD

SESD 271 Vertical Coupling Plate (VCP) for ESD

SESD 272 Grounding cable for ESD

SESD 272 Grounding cable for ESD

SESD 8800-4: ESD Verification Set

SESD 8800-4: ESD Verification Set

CLP40K, 400 A, Charge line generator, POE

CLP40K, 400 A, Charge line generator, POE

CLP5K, 50A, Charge line generator, POE

CLP5K, 50A, Charge line generator, POE

Products

CABCI251R, 200W, 1.0 Ohm Shunt Resistor

1.0 Ohm 1% Shunt Resistor, 200W

  • used in MIL-STD, FORD, and other standards
  • Low Inductance
  • High Precision

PG-C202 - Damped Sinusoid Generator CS116 +7dB levels

Special custom generator for high current DOW testing

  • High Current Capability: Up to CS116 +7dB for direct injection, 23 A with the optional coupling clamp.
  • Wide Frequency Range: Operates from 10, 100 kHz 1, 10, 30, 100 MHz - expandable to 12 frequencies
  • Automation Ready: Fully computer-controlled with RS232 and USB interfaces for calibration, operation, and report generation.
  • Efficient Testing: Single output connection eliminates reconnections, significantly reducing test time.

Optimize your naval and industrial testing with the CS116 Damped Sinusoid Generator—precision and efficiency combined.

PG-C201 - Damped Sinusoid Generator 300A

Special custom generator for high current DOW testing

  • High Current Capability: Up to 300 A for direct injection and 75 A with the optional coupling clamp.
  • Wide Frequency Range: Operates from 100 kHz to 55 MHz with 10 discrete frequencies (expandable to 10 kHz–100 MHz on request).
  • Automation Ready: Fully computer-controlled with RS232 and USB interfaces for calibration, operation, and report generation.
  • Efficient Testing: Single output connection eliminates reconnections, significantly reducing test time.

Optimize your naval and industrial testing with the CS116 Damped Sinusoid Generator—precision and efficiency combined.

Customized PCI Generators

  • Tailored to Your Requirements – Custom-designed EMP and PCI solutions for specific voltage, waveform, and test conditions.
  • Industry-Leading Fast Pulse Technology – Ensuring precision, repeatability, and compliance with global standards.
  • Wide Voltage & Frequency Range – Custom solutions from 5 kV to over 500 kV, optimized for MIL-STD-188-125 and IEC 61000-4-25 testing.
  • Seamless Integration & AutomationRS232, USB, and fiber optic control for efficient remote operation.
  • Turnkey Testing & Data Acquisition – Compatible with Montena’s PULSELab software, ensuring real-time monitoring and analysis.
  • Proven Global Expertise – Montena’s extensive EMP and PCI system portfolio guarantees reliable and compliant solutions for any application.

EMP300K-5-500, PCI Short pulse (E1) generator, 5kA

EMP300K-5-500 PCI 5kA Pulse Generator 

  • MIL-STD-188-125-1/2 Compliant – Ensures precise pulse current injection (PCI) testing for EMP protection validation.
  • High-Voltage Performance – Delivers up to 350kV pulses with a peak 5kA short-circuit current.
  • Fast & Repeatable Pulses – Ultra-fast and 500-550 ns pulse duration for accurate testing.
  • Fully Automated & Computer-ControlledRS232 & USB interfaces enable seamless remote operation.
  • Comprehensive Accessory Support – Compatible with current probes, CDNs, fiber optic links, and automation software for a complete test setup.

IPP3K-4MS, 260A, Intermediate Pulse (E2) Generator

 IPP3K-4MS PCI Intermediate Pulse Generator 

  • MIL-STD-188-125-1/2 Compliant – Designed for precise EMP protection testing.
  • High-Voltage Performance3.0 kV charging voltage with 260 A peak short-circuit current.
  • Fast & Repeatable Pulses and 3 – 5 ms pulse duration for accurate testing.
  • Multi-Line Direct Coupling4 independent outputs for testing power, signal, and telecom lines.
  • Fully Automated ControlRS232 & USB interfaces for seamless operation & remote testing.
  • Complete Testing Solution – Compatible with current probes, CDNs, fiber optic links & optional automation software.

SESD 302x Test tip's for ESD

Avalible ESD Test Tips for replacment or different aplications.

SESD 271 Vertical Coupling Plate (VCP) for ESD

The Vertical Coupling Plate (VCP) is used in conjunction with ESD generators to simulate indirect discharges on metallic objects that are near a test object. The bleeder resistors contained in the ground wire of the VCP serve to prevent the applied charge from vanishing immediately after the discharge of the ESD generator to the VCP, thereby increasing the effect of the ESD test.

SESD 272 Grounding cable for ESD

2m Grounding cable for ESD immunity tests

SESD 8800-4: ESD Verification Set

ESD - Generators verified according to the standard International Electro technical Commission 61000-4-2, ISO 10605 and other. The measurements of the single pulses take place with a special 2 ohm shunt. For the correct verification of the ESD impulses an oscilloscope is necessary with a minimum bandwidth of - 2 GHz acc. IEC 61000-4-2, 2008 and - 1 GHz acc. ISO 10605, 2008. The ESD verification set SESD 8800-4 works up to 4 GHz and fulfilled the request of the double bandwidth regarding to the measurement bandwidth.

CLP40K, 400 A, Charge line generator, POE

  • MIL-STD-188-125-2 Compliant – Designed for pulse current injection (PCI) testing of antenna POE protective devices.
  • Adjustable High-Voltage Pulses0.2 - 25 kV, 400A (CLP40K) for precise testing.
  • Broad Frequency Coverage – Supports testing from 30 MHz up to 477.5 MHz with variable charge line plugs.
  • Ultra-Fast Pulse Rise Time and for high-speed transient testing.
  • Direct Coaxial Coupling – No external coupling device required for efficient pulse injection.
  • Automated Operation & Remote ControlRS232 & USB interfaces for seamless integration and monitoring.
  • Complete Test Solution – Includes charge line plugs, current probes, fiber optic links, and optional Montena PULSELab software.

CLP5K, 50A, Charge line generator, POE

  • MIL-STD-188-125-2 Compliant – Designed for pulse current injection (PCI) testing of antenna POE protective devices.
  • Adjustable High-Voltage Pulses –  0.05 - 5 kV, 50Amps (CLP5K) for precise testing.
  • Broad Frequency Coverage – Supports testing from 30 MHz up to 477.5 MHz with variable charge line plugs.
  • Ultra-Fast Pulse Rise Time and for high-speed transient testing.
  • Direct Coaxial Coupling – No external coupling device required for efficient pulse injection.
  • Automated Operation & Remote ControlRS232 & USB interfaces for seamless integration and monitoring.
  • Complete Test Solution – Includes charge line plugs, current probes, fiber optic links, and optional Montena PULSELab software.

Loading...