Categories

IPG 1201, Insulation Tester, 12kV

IPG 1201, Insulation Tester, 12kV

IPG 2025 / IPG 2436, Impulse Wave Generator 20kV or 24kV

IPG 2025 / IPG 2436, Impulse Wave Generator 20kV or 24kV

CAR PG 2804 Load Dump Generator

CAR PG 2804 Load Dump Generator

HTS 20-10, 20 kV, DC dielectric strength

HTS 20-10, 20 kV, DC dielectric strength

IPG 2553: Oscillatory Wave Generator

IPG 2553: Oscillatory Wave Generator

Customized PCI Generators

Customized PCI Generators

IPG 612T: 6kV RING-WAVE GENERATOR

IPG 612T: 6kV RING-WAVE GENERATOR

PG 12-400, 12kV, Impulse Wave Generator

PG 12-400, 12kV, Impulse Wave Generator

PG-C202 - Damped Sinusoid Generator CS116 +7dB levels

PG-C202 - Damped Sinusoid Generator CS116 +7dB levels

PG-C201 - Damped Sinusoid Generator 300A

PG-C201 - Damped Sinusoid Generator 300A

IPG 1218 / 1012 / 605, Insulation Test, 12kV, 10kV, 6.25kV

IPG 1218 / 1012 / 605, Insulation Test, 12kV, 10kV, 6.25kV

IPG 255, Insulation Tester, 8kV

IPG 255, Insulation Tester, 8kV

Products

IPG 1201, Insulation Tester, 12kV

The High-Voltage Pulse Generator IPG 1201 is designed for testing of impulse dielectric strength of components, insulation, air- and surface flashover gaps. It is specially used for testing surge withstand capability of insulation between accessible parts and hazardous live parts, e.g. terminals for connection of antenna and mains supply terminals, refer to EN 60065. Picture: incl. Option PA 503

IPG 2025 / IPG 2436, Impulse Wave Generator 20kV or 24kV

The HV - Impulse generators IPG 2025 and IPG 2436 create standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. They are designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps according to the standards. The peak value of the test voltage is continuously adjustable from 2 - 20 kV or 2 - 24 kV. Positive or negative polarity of output voltage can be selected. A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.

CAR PG 2804 Load Dump Generator

Compact EMC test unit designed for testing electromagnetic immunity of the electrical installation of vehicles and components against supply line transients. PG 2804 includes the generation of pulses #5 / Test A and Test B. It is designed to be connected to the power supply interface of the CAR-TESTER. Load Dump Generator EMC-Test Equipment for the electrical installation of vehicles.

  • Puls #5 / Test A / Test B
  • Ri = 0.5 / 1 / 2 / 4 / 8 Ω
  • Used with CAR-SYS 14 or independently with Coupling Network. 

HTS 20-10, 20 kV, DC dielectric strength

High-Voltage DC Test Sets HTS 20-10 are designed for testing dc dielectric strength of components, insulations, air- and surface flash-over gaps. Also for testing SPDs according to IEC 61643-1. The test voltage can be adjusted from 0.2 kV up to 20 kV. The test voltage rises like a ramp from zero to the selected test voltage. The rate of rise can be adjusted from 100 V/sec up to 10000 V/sec. Then the test voltage remains at the selected value for the test time, which can be adjusted from 1 – 1000 sec. Figure: incl. option PA503

IPG 2553: Oscillatory Wave Generator

The oscillatory wave generator IPG 2553 has been designed for immunity testing of electrical and electronic equipment against repetitive damped oscillatory magnetic field according to IEC 61000-4-10 requirements. It generates a decaying cosine current waveform with ringing frequency of 100 kHz or 1.0 MHz. The generator output is connected to special designed Helmholtz-coil which generates magnetic field with 10 - 100 A/m.

Customized PCI Generators

  • Tailored to Your Requirements – Custom-designed EMP and PCI solutions for specific voltage, waveform, and test conditions.
  • Industry-Leading Fast Pulse Technology – Ensuring precision, repeatability, and compliance with global standards.
  • Wide Voltage & Frequency Range – Custom solutions from 5 kV to over 500 kV, optimized for MIL-STD-188-125 and IEC 61000-4-25 testing.
  • Seamless Integration & AutomationRS232, USB, and fiber optic control for efficient remote operation.
  • Turnkey Testing & Data Acquisition – Compatible with Montena’s PULSELab software, ensuring real-time monitoring and analysis.
  • Proven Global Expertise – Montena’s extensive EMP and PCI system portfolio guarantees reliable and compliant solutions for any application.

IPG 612T: 6kV RING-WAVE GENERATOR

IPG 612T RING-WAVE GENERATOR is a High-voltage pulse generator producing Ring Wave 0.5 µs / 100 kHz acc. to IEC 61000-4-12. The output peak voltage can be preset continuously from 0.2 - 6 kV. Rise time 0.5µs to the first peak, ringing frequency 100 kHz. The picture is shown with PA 503 Option.

PG 12-400, 12kV, Impulse Wave Generator

High-Voltage Pulse Generator PG 12-400 generates standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. It is designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps acc. to IEC.

PG-C202 - Damped Sinusoid Generator CS116 +7dB levels

Special custom generator for high current DOW testing

  • High Current Capability: Up to CS116 +7dB for direct injection, 23 A with the optional coupling clamp.
  • Wide Frequency Range: Operates from 10, 100 kHz 1, 10, 30, 100 MHz - expandable to 12 frequencies
  • Automation Ready: Fully computer-controlled with RS232 and USB interfaces for calibration, operation, and report generation.
  • Efficient Testing: Single output connection eliminates reconnections, significantly reducing test time.

Optimize your naval and industrial testing with the CS116 Damped Sinusoid Generator—precision and efficiency combined.

PG-C201 - Damped Sinusoid Generator 300A

Special custom generator for high current DOW testing

  • High Current Capability: Up to 300 A for direct injection and 75 A with the optional coupling clamp.
  • Wide Frequency Range: Operates from 100 kHz to 55 MHz with 10 discrete frequencies (expandable to 10 kHz–100 MHz on request).
  • Automation Ready: Fully computer-controlled with RS232 and USB interfaces for calibration, operation, and report generation.
  • Efficient Testing: Single output connection eliminates reconnections, significantly reducing test time.

Optimize your naval and industrial testing with the CS116 Damped Sinusoid Generator—precision and efficiency combined.

IPG 1218 / 1012 / 605, Insulation Test, 12kV, 10kV, 6.25kV

High-Voltage Pulse Generators IPG 1218 / 1012 / 605 generate standard impulse voltages with waveform 1.2 / 50 µs acc. to IEC 60060. They are designed for testing impulse dielectric strength of components, insulations, air- and surface flash-over gaps acc. to IEC. The peak value of the test voltage is continuously adjustable from 0.2 - 6.25 / 10 / 12 kV. Positive or negative polarity of the output voltage can be selected. A built-in voltage divider 1000:1 allows monitoring of the impulse output waveform during testing.

IPG 255, Insulation Tester, 8kV

The High-Voltage Pulse Generator IPG 255 is designed for testing of impulse dielectric strength of components, insulation, air-and surface flash-over gaps of watt-hour meters, static relays etc. according to IEC 60255, EN 61036, VDE 0435 part 303. Picture: incl. Option PA 503