TBPCP3 RF pulse current monitoring probes

TBPCP3 RF pulse current monitoring probes

TBPCP4 RF pulse current monitoring probes

TBPCP4 RF pulse current monitoring probes

CDG CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDG CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

EMCVIEW PC SOFTWARE PRE-COMPLIANCE TESTING

EMCVIEW PC SOFTWARE PRE-COMPLIANCE TESTING

TBFL1 - Transient Limiter

TBFL1 - Transient Limiter

TBOH02 - Self Powered Active Load

TBOH02 - Self Powered Active Load

CalStan 11.0 - RF Measurement Software

CalStan 11.0 - RF Measurement Software

CDG CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDG CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDG CMP-46 Current Monitoring Probe, with Calibration Set

CDG CMP-46 Current Monitoring Probe, with Calibration Set

TBCG4 1 GHz USB-C Comb Generator

TBCG4 1 GHz USB-C Comb Generator

TBCG5 3 GHz USB-C Comb Generator

TBCG5 3 GHz USB-C Comb Generator

Products

TBPCP3 RF pulse current monitoring probes

RF pulse current monitoring probes

Family of RF pulse-current probes for monitoring transient currents over low-frequency-to-RF bandwidths.

  • Characterized frequency range: 0.1 Hz to 100 MHz
  • 3 dB bandwidth: 2 Hz to 40 MHz (measured in a 50 + 50 Ohm loop)
  • Transfer impedance into 50 ? load: -20 dB?; 0.1 V/A
  • Transfer impedance into high Z: 0.2 V/A
  • Probe port impedance: 50 ?

TBPCP4 RF pulse current monitoring probes

RF pulse current monitoring probes

Family of RF pulse-current probes for monitoring transient currents over low-frequency-to-RF bandwidths.

  • Characterized frequency range: 0.1 Hz to 100 MHz
  • 3 dB bandwidth: 1 Hz to 30 MHz (measured in a 50 + 50 Ohm loop)
  • Transfer impedance into 50 ? load: -26 dB?; 0.05 V/A
  • Transfer impedance into high Z: 0.1 V/A
  • Probe port impedance: 50 ?

CDG CDN BCI-P1 Bulk Current Injection Probe 1 MHz – 400 MHz

BCI-P1 Bulk Current Injection Probe 10 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005 and IEC 61000-4-6 - Frequency range from 1 MHz up to 400 MHz - Designed for automotive BCI testing - Low insertion loss (1MHz - 400MHz) to test bellow 1MHz (IEC/DO/MIL) see CDN BCI-P1_MT-1

CDG CMP-45 Current Monitoring Probe, Foldable, with Calibration Set

CDG CMP-45 Current monitoring probe • Cable diameters up to 45 mm • Frequency range 10 kHz to 400 MHz • Foldable, easy positioning on the conductor / cable • For BCI testing acc. to ISO 11452-4 and others • Insertion impedance < 2,5 ?

EMCVIEW PC SOFTWARE PRE-COMPLIANCE TESTING

The Tekbox EMC compliance software EMCview for PCs is a user friendly EMC pre-compliance testing of radiated and conducted emissions. It is a perfect complement for automated testing using our LISNs and TEM Cells. A built in amplitude correction enables correction and conversion coefficients for cables, amplifiers, attenuators, LISNs, TEM cells, antennas, RF current probes, striplines and capacitive coupling clamps.

TBFL1 - Transient Limiter

The TBFL1 is a combined transient limiter/attenuator/ high pass filter, designed to provide optimum protection of spectrum analyzer or measurement receiver inputs when carrying out conducted noise measurements or other measurements where the input levels cannot be predicted with certainty or where accidental overloads may occur.

TBOH02 - Self Powered Active Load

The TBOH02 is a self-powered, precision active load. It does not need a separate supply voltage and operates as low as 2V. Its features include constant resistance and constant current mode. A 10 turn potentiometer with dial, a range switch and a precision reference enable the accurate setting of current or resistance. Furthermore, it can be controlled by an external voltage.

CalStan 11.0 - RF Measurement Software

CalStan 11 is a software tool for automation of radio frequency (RF) calibrations and measurements of EMC test sites and test equipment. The software controls the instruments via GPIB bus and LAN, reads the measurement values and computes the results. A modular concept with measurement plug-ins allows customization according to the test lab requirements.

CDG CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz

CDG CDN BCI-P1_MT-1 Bulk Current Injection Probe 4 kHz – 400 MHz - Meets specifications of ISO 11452-4:2005, MIL-STD-461, DO-160 and IEC 61000-4-6 - Frequency range from 4 kHz up to 400 MHz - Designed for BCI testing 

CDG CMP-46 Current Monitoring Probe, with Calibration Set

CDG CMP-46 Current monitoring probe • Cable diameters up to 45 mm • Frequency range 10 kHz to 400 MHz • For BCI testing acc. to ISO 11452-4 and others • Insertion impedance < 2,5 ?

TBCG4 1 GHz USB-C Comb Generator

1 GHz USB-C Comb Generator

  • 5 MHz–1 GHz characterized spectrum
  • 5 MHz, 10 MHz or 20 MHz comb spacing
  • 50 Ω SMA female RF output
  • Typical line amplitudes −38 dBm at 5 MHz spacing and −28 dBm at 10 MHz spacing, each ±3 dB
  • Less than 300 ps pulse rise time; less than 10 dB spectrum flatness

TBCG5 3 GHz USB-C Comb Generator

3 GHz USB-C Comb Generator

  • 50 MHz, 100 MHz or 200 MHz comb spacing
  • Characterized through 3 GHz; usable to 8 GHz per TekBox
  • Typical line amplitudes above the sixth harmonic: −20, −10 or −5 dBm for 50, 100 or 200 MHz spacing respectively, each ±3 dB
  • Less than 10 dB typical flatness above the sixth harmonic through 3 GHz
  • Less than 150 ps pulse rise time; 50 Ω SMA female RF output

Loading...