The TBCP2-250, -500, -750 -30K400 are snap-on RF current monitoring probes with very flat response of a 3dB bandwidth.
The TBCG1 is a radiating comb generator with an internal antenna and a base frequency of 100MHz. It radiates a comb spectrum characterized up to 6GHz. The comb generator is built and characterized to serve as a rough reference for testing radiated noise measurement set ups in anechoic chambers, TEM/GTEM cells, shielded chambers, etc.
The TBCG2 is a passive, step recovery diode based comb generator/frequency multiplier. It is optimized for moderate drive power and spectrum flatness in the frequency range 1 MHz to 2.5GHz. The recommended drive power is +10 dBm to +20 dBm The frequency range for the drive signal is 1 MHz to 350MHz
The TBAS3 RF 10W attenuator set consists of a 3dB, 6dB, 10dB and 20dB attenuator in a beech wood box.
The TBSCP1-10M500 is a RF surface current monitoring probe that has a very flat response from 10MHz to 500 MHz and is characterized over the frequency range from 30 kHz to 600 MHz.
The TBAS2 RF SMA attenuator/termination set consists of a 3dB, 6dB, 10dB, 15dB, 20dB and 30dB SMA attenuators in a beechwood box. Furthermore, it contains two pieces SMA 50 Ohm terminations.
The TBCG3-RN2 comb generator is primarily intended for testing radiated emission setups. It is a useful tool for validating the proper operation of the antenna and pre-amplifier, as well as the accurate set-up and configuration of the spectrum analyzer.
The TBCDN-M1 is a Coupling Decoupling Network for conducted immunity testing according to IEC 61000-4-6. The TBCDN-M1 is compliant with IEC 61000-4-6 Annex D2.
The TBCG3-RN6 comb generator is primarily intended for testing radiated emission setups. It is a useful tool for validating the proper operation of the antenna and pre-amplifier, as well as the accurate set-up and configuration of the spectrum analyzer.
The TBCCP1-400K600 is a coaxial RF current monitoring probe with a 3 dB bandwidth from 400 kHz to 600 MHz and a very flat response from 1 MHz to 200 MHz.
The TBCP3-1000 is a fixed aperture RF current monitoring probe. It has a very flat response with a 3dB bandwidth of 1 GHz and is characterized and usable over the frequency range from 30kHz to 1 GHz.
The aperture of the RF current monitoring probe is 17 mm. Its transfer impedance is close to 20 dB Ohm in the range from 3 MHz to 1 GHz.
The TBCP4-250, -500, and -750 is a fixed aperture RF current monitoring probe, it has a very flat response with a 3dB bandwidth of 750 MHz and is characterized and usable over the frequency range from 10kHz to 800 MHz. The aperture of the RF current monitoring probe is 32 mm. Its transfer impedance is close to 14 dB Ohm in the range from 400 kHz to 750 MHz.